Treatment Planning and Dose Calculation in Radiation Oncology 1982
DOI: 10.1016/b978-0-08-027176-7.50008-1
|View full text |Cite
|
Sign up to set email alerts
|

Radiation Physics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…The radiation doses of 11 In-DOTA-EB-cRGDfK from such an administration for the lower large intestine, kidney, and liver were 0.138 Gy, 0.048 Gy, and 0.042 Gy, respectively. Compare to the tolerance of normal tissues to radiation doses are 25 Gy, 20 Gy, and 8 Gy, respectively [ 36 ], we found that the radiation absorbed dose was low and does not affect the human body. This shows the safety of the drug and is also conducive to future related trials of labeling for therapeutic radionuclides.…”
Section: Discussionmentioning
confidence: 63%
“…The radiation doses of 11 In-DOTA-EB-cRGDfK from such an administration for the lower large intestine, kidney, and liver were 0.138 Gy, 0.048 Gy, and 0.042 Gy, respectively. Compare to the tolerance of normal tissues to radiation doses are 25 Gy, 20 Gy, and 8 Gy, respectively [ 36 ], we found that the radiation absorbed dose was low and does not affect the human body. This shows the safety of the drug and is also conducive to future related trials of labeling for therapeutic radionuclides.…”
Section: Discussionmentioning
confidence: 63%
“…The maximum tolerance dose (MTD) is defined as the dose that results in a 5% probability of complication within 5 years (TD 5/5). The reported respective MTDs for vital organs such as the liver, lungs, and red marrow are 25 Gy, 15 Gy, and 1.85 Gy [16, 45, 46]. After injection with 111 MBq 188 Re-liposome, this study shows that the doses that are absorbed by the liver (0.10 Gy), lung (0.06 Gy), kidney (0.04 Gy), and red marrow (0.01 Gy) are much lower than the vital organ maximum tolerance doses.…”
Section: Discussionmentioning
confidence: 99%
“…[ 14 ] The treatment planning system (TPS) is based on computed tomography (CT) scan images and prescribed dose to the tumor. [ 15 ] According to the inherent features of CT images, the value of a pixel in the CT image is calculated by comparing the linear attenuation coefficient of tissue with linear attenuation coefficient of water. [ 16 ] CT images in treatment planning are used as the gold standard.…”
Section: Introductionmentioning
confidence: 99%