2014
DOI: 10.1016/j.talanta.2014.02.023
|View full text |Cite
|
Sign up to set email alerts
|

Rapid analysis of persistent organic pollutants by solid phase microextraction in serum samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 39 publications
0
11
0
Order By: Relevance
“…Flores‐Ramirez et al. studied the biomonitoring of PCBs and OCPs in children's serum ( n = 96) collected from Mexico [60]. They found relatively high concentrations of PCB congeners and OCPs in Mexican children compared to the United States, Spain, Rumania, and Germany.…”
Section: Resultsmentioning
confidence: 99%
“…Flores‐Ramirez et al. studied the biomonitoring of PCBs and OCPs in children's serum ( n = 96) collected from Mexico [60]. They found relatively high concentrations of PCB congeners and OCPs in Mexican children compared to the United States, Spain, Rumania, and Germany.…”
Section: Resultsmentioning
confidence: 99%
“…This trend is confirmed in the last lustrum since most of the published works on this topic have been directed, as well as to the assay of markers of several pathological conditions [210][211][212], toward the determination of several contaminants in urine samples [14,74,83,[213][214][215][216][217][218][219]. Few studies focused on hair [220][221][222], three papers were published about analysis in blood/serum [29,223,224], and one regarding meconium [225]. Some studies reporting the application of SPME for the analysis of urine have employed commercially available coatings such as Car/PDMS [214,216], PDMS/DVB [215], PDMS [217], and PA [14] for the extraction and further analysis of different contaminants such as VOCs [214,216], aromatic amines [215], organochlorine pesticides [217], and benzothiazoles, benzotriazoles, benzosulfonamides [14].…”
Section: The Final Endpoint: Bio-clinical Matricesmentioning
confidence: 86%
“…For this matrix, the porous structural surface together with the dual extraction mechanisms demonstrated that the SPME probe has an outstanding enrichment capacity, enhancing sensitivity by approximately 100-500 folds. In another application regarding the analysis in serum, a novel mesoporous graphitic carbon nitride@NiCo 2 O 4 nanocomposite-based fiber was prepared and used for sensitive determination of PCBs and PAHs in headspace mode [224], whereas the commercial PDMS fiber was employed in order to analyze organochlorine pesticides and PCBs levels again in headspace mode [223]. To investigate fetal exposure to volatile organic compounds, a method was developed to identify and quantify BTEX and two chlorinated solvents (trichloroethylene and tetrachloroethylene) in meconium [225].…”
Section: The Final Endpoint: Bio-clinical Matricesmentioning
confidence: 99%
“…PCB levels will be measured using gas chromatography–mass spectrometry. 18 19 In addition to total concentration, the composition of major individual congeners will also be analysed and the source of exposure inferred. The associations between congener composition and outcomes will also be analysed.…”
Section: Cohort Descriptionmentioning
confidence: 99%