2021
DOI: 10.1111/jfpp.15262
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and nondestructive determination of qualities in vacuum‐packaged catfish (Clarias leather) fillets during slurry ice storage

Abstract: This study investigated the effect of different site and vacuum package on catfish quality during slurry ice storage and feasibility of rapid detection of fillet quality using near infrared spectroscopy (NIRs). The results showed the nutrients content of fillet had significant difference (p < .05) between front and rear mid-line site in catfish (using the ventral back end as the mid-line). After 30 days slurry ice storage, drop loss and ΔΕ significantly increased to 6.04% and 5.92, respectively. Total volatile… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 27 publications
0
4
0
Order By: Relevance
“…1). This observation is likely the result of production of alkaline substances of endogenous enzymes and bacteria, such as ammonia and trimethylamine (Cao et al, 2021).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…1). This observation is likely the result of production of alkaline substances of endogenous enzymes and bacteria, such as ammonia and trimethylamine (Cao et al, 2021).…”
Section: Resultsmentioning
confidence: 99%
“…The drip loss of fish fillets increased throughout storage. Drip loss is consisting of loosely bound water and soluble substances, as a result of ruptured structure, protein degradation and rigor state (Cao et al, 2021). No significant difference was observed among samples.…”
Section: Progress In Agricultural Engineering Sciencesmentioning
confidence: 96%
“…The centrifugal was conducted at 1590 g for 10 min. The colour was measured according to the previous method (Cao et al, 2020). The texture was measured by a CT3 texture analyzer according to Zhang et al (2017).…”
Section: Methodsmentioning
confidence: 99%
“…To date, various gas sensors for TMA detection have been developed with good sensing performance, including resistance sensors [8][9][10], colorimetric sensors [11][12][13][14], biosensors [15,16], kinetics methods [17] and spectral imaging [18][19][20]. However, these sensors generally have certain deficiencies, such as high operating temperature, poor stability and insufficient detection limit of TMA below its odor threshold [5,21].…”
Section: Introductionmentioning
confidence: 99%