2022
DOI: 10.1016/j.psj.2022.101860
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and visual detection of Mycoplasma synoviae by recombinase-aided amplification assay combined with a lateral flow dipstick

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…Of the ten paper-based RAA articles incorporated in this review, all reported paper-based detection but did not show paper-based extraction or amplification. Nine articles reported colorimetric detection using tagged probes/primers and AuNPs [ 58 , 59 , 60 , 61 , 62 , 63 , 64 ]. For example, Xu et al used LFIA to detect Amphidinium carterae by implementing a species-specific primer tagged with biotin and a probe labeled with FAM [ 62 ].…”
Section: Raa and Mira With Paper Microfluidicsmentioning
confidence: 99%
“…Of the ten paper-based RAA articles incorporated in this review, all reported paper-based detection but did not show paper-based extraction or amplification. Nine articles reported colorimetric detection using tagged probes/primers and AuNPs [ 58 , 59 , 60 , 61 , 62 , 63 , 64 ]. For example, Xu et al used LFIA to detect Amphidinium carterae by implementing a species-specific primer tagged with biotin and a probe labeled with FAM [ 62 ].…”
Section: Raa and Mira With Paper Microfluidicsmentioning
confidence: 99%
“…These methods are not convenient to use in limited feeding conditions because of the need for cumbersome precision thermal cycler equipment. Additionally, isothermal amplification technology has rapidly developed in recent years, including recombinase polymerase amplification ( RPA ) and loop-mediated isothermal amplification ( LAMP ) ( Kursa et al, 2015 ; Xia et al, 2022 ). The methods can be completed under constant temperature; however, the specificity is poor, and false-negatives or false-positives are easily generated.…”
Section: Introductionmentioning
confidence: 99%
“…When the control line and the test line simultaneously color, a positive result is indicated; a result than can be detected by the human eye. Indeed, LFD is a convenient assay for immediate visualization after the rapid amplification of RPA (Xia et al, 2022). Compared with traditional gel electrophoresis detection, LFDs main advantages are that a result can be observed within 1-2 minutes, without the need for precision instruments such as imagers .…”
Section: Introductionmentioning
confidence: 99%