2009
DOI: 10.1016/j.chroma.2008.10.107
|View full text |Cite
|
Sign up to set email alerts
|

Rapid determination of ethylene oxide with fiber-packed sample preparation needle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
26
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
9
1

Relationship

5
5

Authors

Journals

citations
Cited by 42 publications
(27 citation statements)
references
References 40 publications
1
26
0
Order By: Relevance
“…[9][10][11][12][13][14] By introducing fine fibrous materials as the extraction medium, several novel microscale sample preparation techniques were developed based on excellent resistance to typical organic solvents. [15][16][17][18][19][20][21][22] These fibrous materials were also employed as a stationary phase in GC, because of their excellent thermal stability over the temperature range typically used in most of GC separations. [23][24][25][26][27] Coated with typical polysiloxane-based materials onto the surface of the fibrous materials, the retentivity was significantly improved, and also the selectivity could be designed on the basis of the type of polymeric coatings.…”
Section: Introductionmentioning
confidence: 99%
“…[9][10][11][12][13][14] By introducing fine fibrous materials as the extraction medium, several novel microscale sample preparation techniques were developed based on excellent resistance to typical organic solvents. [15][16][17][18][19][20][21][22] These fibrous materials were also employed as a stationary phase in GC, because of their excellent thermal stability over the temperature range typically used in most of GC separations. [23][24][25][26][27] Coated with typical polysiloxane-based materials onto the surface of the fibrous materials, the retentivity was significantly improved, and also the selectivity could be designed on the basis of the type of polymeric coatings.…”
Section: Introductionmentioning
confidence: 99%
“…Alternative sample preparation techniques have been developed as a needle-type sample preparation device. [7][8][9][10][11][12][13][14][15] Compared to the conventional SPME, the needle-type sampling device has been regarded to have good mechanical strength and high extraction capacity. In our previous work, a polymer particulate medium based on a copolymer of methacrylic acid (MA) and ethylene glycol dimethacrylate (EDMA) was synthesized, and packed into a specially-designed needle as the extraction medium.…”
Section: Introductionmentioning
confidence: 99%
“…In-needle derivatization methods were developed for several target analytes with a fiber-packed needle. Because of the inert surface of the fibers, the derivatization reaction in the needle was successfully processed, where the change of the chemical structure of the target analytes during the derivatization reaction make it possible for the derivatives to be extracted more effectively in the needle extraction device [79][80][81][82].…”
Section: Needle-type Sample Preparation Devicementioning
confidence: 99%