2022
DOI: 10.1039/d1an02098f
|View full text |Cite
|
Sign up to set email alerts
|

Rapid identification of bacterial mixtures in urine using MALDI-TOF MS-based algorithm profiling coupled with magnetic enrichment

Abstract: Urinary tract infections (UTIs) are severe public health problem and caused by mono- or poly-bacteria. Culture-based methods are routinely used for the diagnosis of UTIs in clinical practice, but those...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 33 publications
0
6
0
Order By: Relevance
“…Out of the MALDI MS instruments used, Microex of Bruker is the most extensively used instrument for microbial identication. [49][50][51][52][53] Fig. 2 represents the different sample preparation methods that have been in practice for the MALDI MS iden-tication of bacterial isolates.…”
Section: Methods Of Sample Preparationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Out of the MALDI MS instruments used, Microex of Bruker is the most extensively used instrument for microbial identication. [49][50][51][52][53] Fig. 2 represents the different sample preparation methods that have been in practice for the MALDI MS iden-tication of bacterial isolates.…”
Section: Methods Of Sample Preparationsmentioning
confidence: 99%
“…Out of the MALDI MS instruments used, Microflex of Bruker is the most extensively used instrument for microbial identification. 49–53…”
Section: Maldi Ms Spectrum-based Identification Of Microbial Pathogensmentioning
confidence: 99%
“…The Brucker MBT_FC. par method was selected to collect the data automatically [ 18 , 19 ]. The score standards for mass spectrometry identification were as follows: 2.300–3.000 for completely reliable identification at the species level; 2.00–1.99 for identification at the species level; 1.700–1.999 for identification at the genus level; 0.000–1.699 indicated no credible identification.…”
Section: Methodsmentioning
confidence: 99%
“…Considering the unique relationship between PCa and urine biosamples, [42,43] urine is a noninvasive biofluid with unique advantages in detection scenarios. We thus performed MoS 2 /MXene-based UMF analysis on urinary biosamples from 60 PCa and 96 BPH patients (Figure 6a) and all relevant clinical information for biosamples was described in Table S2 (Supporting Information).…”
Section: Smf/umf Of Pca and Bph Via Mos 2 /Mxene Heterostructurementioning
confidence: 99%