2012
DOI: 10.1002/jssc.201200480
|View full text |Cite
|
Sign up to set email alerts
|

Rapid screening and determination of designer drugs in saliva by a nib‐assisted paper spray‐mass spectrometry and separation technique

Abstract: A method for the rapid screening and determination of amphetamine-type designer drugs in saliva by a novel nib-assisted paper spray-mass spectrometry procedure is described. Under optimized conditions, the limit of detections for amphetamine derivatives (model samples: o-, m-, p-chloroamphetamine and o-, m-, p-fluoroamphetamine, respectively) were determined to 0.1 μg/mL by the nib-assisted paper spray-mass spectrometry method. This method is easier and has a higher sensitivity than similar methodologies, incl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(21 citation statements)
references
References 46 publications
0
21
0
Order By: Relevance
“…Although the methodology and specific aims of papers differ, they have a common theme in showing that PS-MS can detect and quantify therapeutic drugs [12], [1], [8], [18], [6], [11], [17], [4], [19], [15], [20], [21] and drugs of abuse [9], [5], [10] (including designer drugs [22], [23]). In many cases, these drugs and metabolites are detected at clinically or physiologically relevant concentrations with good quantitative performance directly from biofluid.…”
Section: A Xenobioticsmentioning
confidence: 99%
“…Although the methodology and specific aims of papers differ, they have a common theme in showing that PS-MS can detect and quantify therapeutic drugs [12], [1], [8], [18], [6], [11], [17], [4], [19], [15], [20], [21] and drugs of abuse [9], [5], [10] (including designer drugs [22], [23]). In many cases, these drugs and metabolites are detected at clinically or physiologically relevant concentrations with good quantitative performance directly from biofluid.…”
Section: A Xenobioticsmentioning
confidence: 99%
“…e mass spectrometer (Finnigan LCQ Classic LC/MS/MS) used in this study was the same instrument that was used in our previous study. 11,[20][21][22] e mass signal was recorded under the full scan mode (m/z 100-400). An Xcalibur data system was used for data collection, and the data were converted into an ASCII text le.…”
Section: Methodsmentioning
confidence: 99%
“…[1][2][3][4][5][6][7][8][9][10][11] Furthermore, since the development of ambient ionization mass spectrometry, socalled paper spray-mass spectrometry (PS-MS) has opened new insights in the eld of mass spectrometric analysis and, since its debut on 2010, it has now become a quite popular and important method for use in mass spectrometry. 12) us far, PS-MS has been applied successfully in many areas of research, including food science, 13) the analysis of protein complexes, 14,15) bio uid samples, 16,17) the online chemical monitoring of cell cultures, 18) rapid discrimination of bacteria, 19) and drugs of abuse in whole blood or saliva, [20][21][22] and even in an ambient organic analysis. 23) Some novel alternate techniques based on PS-MS have also been reported, including a 3D-printed paper spray ionization cartridge/ continuous solvent supply and the rapid detection of cocaine residues by paper spray ionization coupled with ion mobility spectrometry.…”
Section: Introductionmentioning
confidence: 99%
“…In contrast to this, a nib-assisted device can be used to slowly and continually wet the paper, as shown in Figure 6 [20]. Herein, a piece of paper was cut into a triangular shape (5 mm in length and 3 mm wide at the base).…”
Section: Modificationsmentioning
confidence: 99%
“…Nib-assisted paper spray-MS method.Reproduced with permission from[20] © WILEY-VCH Verlag GmbH & Co.…”
mentioning
confidence: 99%