1988
DOI: 10.1016/s0003-2670(00)80444-4
|View full text |Cite
|
Sign up to set email alerts
|

Rapid spectrophotometric determination of total phosphorus in industrial wastewaters by flow injection analysis including a capillary digestor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

1990
1990
2008
2008

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…The molybdenum blue method can be applied to the total phosphorus determination after the decomposition of organic and inorganic phosphorus compounds, organic and inorganic condensed phosphorus compounds, and solid and dissolved phosphorus compounds to orthophosphate by heating at high temperature (120-160 • C) [59,60], at high temperature with a platinum wire in a reaction coil [61], or by irradiating UVlight to aqueous samples containing persulfate [47,55]. By using a reaction coil, which is wound on two low-pressure mercury lamps (14 mm o.d., 134 mm length, 4 W germicidal use), most organic phosphorus compounds were decomposed to orthophosphate at 70 • C: LOD was 1 g/l of phosphorus at 830 nm [55].…”
Section: Trace Analysis For Phosphorus By Flow-injection Techniquementioning
confidence: 99%
See 1 more Smart Citation
“…The molybdenum blue method can be applied to the total phosphorus determination after the decomposition of organic and inorganic phosphorus compounds, organic and inorganic condensed phosphorus compounds, and solid and dissolved phosphorus compounds to orthophosphate by heating at high temperature (120-160 • C) [59,60], at high temperature with a platinum wire in a reaction coil [61], or by irradiating UVlight to aqueous samples containing persulfate [47,55]. By using a reaction coil, which is wound on two low-pressure mercury lamps (14 mm o.d., 134 mm length, 4 W germicidal use), most organic phosphorus compounds were decomposed to orthophosphate at 70 • C: LOD was 1 g/l of phosphorus at 830 nm [55].…”
Section: Trace Analysis For Phosphorus By Flow-injection Techniquementioning
confidence: 99%
“…Later, the mixed reagent solution was improved by the addition of an anionic surfactant together with ethanol [68]. The MG method was applied to the determination of total phosphorus in industrial waste waters by on-line digestion/spectrophotometric FIA [61].…”
Section: Trace Analysis For Phosphorus By Flow-injection Techniquementioning
confidence: 99%
“…The measurement of total phosphorus in water involves digestion of a test sample with persulfate for prolonged periods of time; Ayoagi et al . used a 10-m-long PTFE reactor with a Pt wire inserted in it to catalyze this reaction. They used the wire simply for the purposes of catalysis and not for heating, the reactor was externally heated by immersion in an external hot bath.…”
Section: Resultsmentioning
confidence: 99%
“…The same method was also used for molybdenum determination [132]. A rapid determination of total phosphorus in industrial waste waters, including a capillary digestor, was described by Aoyagi et al [133].…”
Section: Sampling Systemsmentioning
confidence: 99%