“…Arbitrary placement randomly selects a subset of lines to install D-FACTS devices [127]. Full placement is the most expensive method in which D-FACTS devices are installed on every transmission line [128]. However, the detection effectiveness of MTDs under these two placements is not considered.…”
Section: E Moving Target Defensementioning
confidence: 99%
See 1 more Smart Citation
“…Arbitrary placement randomly selects a subset of lines to install D-FACTS devices [127]. Full placement is the most expensive method in which D-FACTS devices are installed on every transmission line [128]. However, the detection effectiveness of MTDs under these two placements is not considered.…”
Section: E Moving Target Defensementioning
confidence: 99%
“…Thus, these two methods must be constructed in the D-FACTS placements, which ensure the detection effectiveness, such as the max-rank placements. Second, the optimization-based operation takes both the economic cost and the detection effectiveness into account, in which the metric of detection effectiveness is maximized or taken as constraints [128], [130]. Finally, the hidden MTD operation method delicately selects D-FACTS setpoints such that all measurements remain the same after MTD is applied [134]- [136].…”
Section: E Moving Target Defensementioning
confidence: 99%
“…Case 0: the conventional ACOPF is applied; Case 1: the proposed ACOPF model with 1 0   and 2 1   is used only to minimize the generation cost; Case 2: the proposed ACOPF model with 1 1000   and 2 1   is used to minimize the generation cost and the system loss. We identify the maximum line power flow using the conventional ACOPF under the default load in MATPOWER, denoted by to be consistent with the D-FACTS setting in [6].…”
Section: Case Studymentioning
confidence: 99%
“…Recently, the concept of MTD has been applied to defend against FDI attacks [13], [14], [9], [15]. In comparison to these works, we are the first to apply MTD for defense against CCPAs.…”
Section: Prior Workmentioning
confidence: 99%