2014
DOI: 10.3791/51937
|View full text |Cite
|
Sign up to set email alerts
|

Real Time Measurements of Membrane Protein:Receptor Interactions Using Surface Plasmon Resonance (SPR)

Abstract: Protein-protein interactions are pivotal to most, if not all, physiological processes, and understanding the nature of such interactions is a central step in biological research. Surface Plasmon Resonance (SPR) is a sensitive detection technique for label-free study of bio-molecular interactions in real time. In a typical SPR experiment, one component (usually a protein, termed 'ligand') is immobilized onto a sensor chip surface, while the other (the 'analyte') is free in solution and is injected over the surf… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…Like all ABC importers BtuC 2 D 2 must associate with its cognate SBP since it is the latter that binds the substrate and delivers it to the transporter. We measured the interaction between BtuC 2 D 2 that had worked or rested at 28 °C and BtuF using Surface Plasmon Resonance 29 . We loaded identical amounts (by mass) of worked or rested BtuC 2 D 2 onto a biosensor chip and then washed the chip 50,000-fold to remove any residual ATP.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Like all ABC importers BtuC 2 D 2 must associate with its cognate SBP since it is the latter that binds the substrate and delivers it to the transporter. We measured the interaction between BtuC 2 D 2 that had worked or rested at 28 °C and BtuF using Surface Plasmon Resonance 29 . We loaded identical amounts (by mass) of worked or rested BtuC 2 D 2 onto a biosensor chip and then washed the chip 50,000-fold to remove any residual ATP.…”
Section: Resultsmentioning
confidence: 99%
“…The procedure for measuring the interaction between BtuC 2 D 2 and BtuF using SPR had been extensively described 28 29 . Briefly, BtuC 2 D 2 (15–20 ng, 1500–2000 RU) was immobilized onto a Ni-NTA biosensor chip (GE healthcare) and FLAG-tagged BtuF was injected at the indicated concentration.…”
Section: Methodsmentioning
confidence: 99%
“…All measurements were performed using a Biacore T200 (GE Healthcare) as extensively as described before (34,35,60). His-HmuUV, His-BtuCD, and His-MolBC were immobilized directly onto nickel-nitrilotriacetic acid biosensor chip (GE Healthcare).…”
Section: Spr Measurementsmentioning
confidence: 99%
“…The sensor chip typically used in BIAcore system, that employs the Kretschmann con iguration [16,17], is a dextran matrix, composed of a thioalkane linker layer (~100 nm thick), that creates an hydrophilic environment for different chemical methods of ligand immobilization, which usually require an amount of ligand immobilized (about 10,000 RU) that corresponds to approximately ≈70 fmol/mm2, and for binding process [18]. The activation of the gold layer and the application of a speci ic coat avoid non-speci ic binding of biomolecules to the activated surface [19]. Furthermore, the dextran matrix allows both ligand immobilization with minimal conformational distortion and maximum access of the binding epitopes of ligand and analyte.…”
Section: Spr Technologymentioning
confidence: 99%