2005
DOI: 10.1021/la0503294
|View full text |Cite
|
Sign up to set email alerts
|

Real-Time QCM-D Immunoassay through Oriented Antibody Immobilization Using Cross-Linked Hydrogel Biointerfaces

Abstract: This report presents the development of pre-cross-linked and in situ cross-linked polyethyleneimine-carboxymethylcellulose antibody immobilization platforms for real-time QCM-D immunoassay of sepsis-related biomarkers. These platforms differ significantly from recent trends in QCM-based assays, a rapidly expanding field given the affordability and sensitivity of the transduction system, by providing ultrafast biointerface deposition through cross-linking of polysaccharides. Using rhIL-1ra (17 kDa), a known sep… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
38
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(44 citation statements)
references
References 31 publications
6
38
0
Order By: Relevance
“…Moreover, the negligible non-specific adsorption of human IgG on NFC surface after the superblock treatment allows the use of NFC films in Biointerphases (2012) immunoassays, where positively charged target molecules are monitored. The amount of immobilized antihuman IgG on activated NFC-film was found to be similar to those reported in the literature [5,32]. It should also be mentioned that the adsorbed amount of human IgG on the antihuman IgG interface was over twofold when compared to published results with anti-hIL-1ra conjugation on CMC-PEI hydrogel [5].…”
Section: Biological Activity Of the Immobilized Antihuman Iggsupporting
confidence: 86%
See 1 more Smart Citation
“…Moreover, the negligible non-specific adsorption of human IgG on NFC surface after the superblock treatment allows the use of NFC films in Biointerphases (2012) immunoassays, where positively charged target molecules are monitored. The amount of immobilized antihuman IgG on activated NFC-film was found to be similar to those reported in the literature [5,32]. It should also be mentioned that the adsorbed amount of human IgG on the antihuman IgG interface was over twofold when compared to published results with anti-hIL-1ra conjugation on CMC-PEI hydrogel [5].…”
Section: Biological Activity Of the Immobilized Antihuman Iggsupporting
confidence: 86%
“…The amount of immobilized antihuman IgG on activated NFC-film was found to be similar to those reported in the literature [5,32]. It should also be mentioned that the adsorbed amount of human IgG on the antihuman IgG interface was over twofold when compared to published results with anti-hIL-1ra conjugation on CMC-PEI hydrogel [5].…”
Section: Biological Activity Of the Immobilized Antihuman Iggsupporting
confidence: 86%
“…EDC/NHS chemistry has been employed as a covalent attachment methodology for immobilization of proteins and also as a method for the preparation of substrates. Carrigan et al 51 used EDC/NHS in two ways, (1) for the cross-linking of polyethylenimine and carboxymethyl cellulose, and (2) for activation of this substrate for protein binding targeting amine and carboxyl functionality. Sun et al 52 took a novel approach to EDC/NHS coupling by introducing NHS reactive groups to random sites on an antibody then using an electric field to preferentially orient the antibody, via its intrinsic dipole, before reaction to the free amines on cysteine immobilized to a gold electrode.…”
Section: B Covalent Binding Targetsmentioning
confidence: 99%
“…51,158 Via this method, protein orientation may be investigated; for instance, an antibody immobilized close to the surface in a flat-on orientation will have a low viscoelastic dissipation, while in contrast, an antibody in head-on or end-on orientation will have a higher viscoelastic dissipation.…”
Section: G Quartz Crystal Microbalancementioning
confidence: 99%
“…However, a label-free immunosensor 6,7 has provoked more interest for many reasons, such as simplicity and real-time compared with the traditional immunoassay technology, like enzyme-linked immunosorbent assay (ELISA) 8 and radioimmunoassay. 9 Among those immunosensors, the capacitive immunosensor has attracted more interest with high sensitivity, rapid test time and common instrumentations [10][11][12][13][14][15] compared with other types of direct biosensors, such as surface plasmon resonance, 16,17 quartz crystal microbalance (QCM), 18 surface acoustic wave, 19 and surface scanning detection. 20 The fabrication of a biocompatible layer is more pivotal to a capacitive immunosensor.…”
Section: Introductionmentioning
confidence: 99%