2018
DOI: 10.1109/tla.2018.8358682
|View full text |Cite
|
Sign up to set email alerts
|

Real-Time Simulation of a Luenberger Observer Applied to DC-DC Converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…The sentence discusses how a certain feature the inductive current to accurately follow the reference current and input voltage phase.This results in enhancing the power factor and minimizing toal harmonic distortion. By successfully monitoring the precise amplitude of the specified reference current and the corresponding phase angle of the input voltage, the inductor current can effectively correspond to them, leading to an improvement in the power factor and a reduction in total harmonic distortion.When the cost function reaches its minimum, indicating that the estimated value perfectly matches the reference value, the duty cycle can be determined by utilizing Equation (12).The system control diagram is shown in Figure 4.…”
Section: Observer Designmentioning
confidence: 99%
See 1 more Smart Citation
“…The sentence discusses how a certain feature the inductive current to accurately follow the reference current and input voltage phase.This results in enhancing the power factor and minimizing toal harmonic distortion. By successfully monitoring the precise amplitude of the specified reference current and the corresponding phase angle of the input voltage, the inductor current can effectively correspond to them, leading to an improvement in the power factor and a reduction in total harmonic distortion.When the cost function reaches its minimum, indicating that the estimated value perfectly matches the reference value, the duty cycle can be determined by utilizing Equation (12).The system control diagram is shown in Figure 4.…”
Section: Observer Designmentioning
confidence: 99%
“…In this article, an algorithm is proposed that includes the addition of a Luenberger observer to estimate the inductor current without the need for additional sensors for measurement. A method was presented in [12][13] that applies the Luenberger observer to a DC converter, utilizing voltage and current parameters within the DC converter to detect potential faults in the converter. This approach serves as a means to identify and diagnose any malfunctions or issues within the DC converter, ensuring its reliability and proper operation.…”
Section: Introductionmentioning
confidence: 99%
“…In fact, many types of estimators and filters are widely used in many areas [22, 23] including the notable Kalman filter [24] and filter [25, 26]. Particularly, the classic Luenberger‐type observer has also been proved to be an efficient tool for state estimation [27, 28]. However, the classical Luenberger observers might lead to negative estimations, so they are not adequate for estimating states that are inherently non‐negative.…”
Section: Introductionmentioning
confidence: 99%