Real Time Three‐Dimensional Echocardiographic Evaluations of Fetal Left Ventricular Stroke Volume, Mass, and Myocardial Strain: In Vitro and In Vivo Experimental Study

Abstract: RT3DE is capable of quantifying the SV, LVM, and myocardial strain of fetal-sized hearts under different conditions. This nongated RT3DE may aid the evaluation of fetal cardiac function, providing a superior understanding of the progress of fetal heart disorders.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 54 publications
0
7
0
Order By: Relevance
“…STE provides deformation information of the LV, which has been reported to be valuable in identifying preclinical or subtle myocardial dysfunction. 14 16 , 26 , 30 STE has been used in TAV to evaluate cardiac mechanics in AS and AR patients, which revealed lower deformation in asymptomatic/symptomatic patients with normal LVEF when compared with healthy controls. 17 20 Few reports are available on BAV cardiac mechanics, 31 – 33 and none of them reported the subtle mechanical changes based on valvular lesion types.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…STE provides deformation information of the LV, which has been reported to be valuable in identifying preclinical or subtle myocardial dysfunction. 14 16 , 26 , 30 STE has been used in TAV to evaluate cardiac mechanics in AS and AR patients, which revealed lower deformation in asymptomatic/symptomatic patients with normal LVEF when compared with healthy controls. 17 20 Few reports are available on BAV cardiac mechanics, 31 – 33 and none of them reported the subtle mechanical changes based on valvular lesion types.…”
Section: Discussionmentioning
confidence: 99%
“…3D-STE with higher temporal resolution would provide superior evaluation of subtle cardiac mechanic dysfunction. 14 , 16 , 30 Future 3D-STE studies on BAV deformation are necessary.…”
Section: Limitationsmentioning
confidence: 99%
“…The new iSTIC technology acquires high-resolution volumetric images of one cardiac cycle in only 2 s, thus reducing the effects of fetal movement on the image. iSTIC realizes real-time 3D visualization of the fetal heart, which has been shown to have many advantages[24,25,27-29]. In the present study, the iSTIC technique was used to measure right ventricular volume in normal fetuses and to evaluate right ventricular systolic function to provide a new method for more accurate and convenient evaluation of fetal heart function.…”
Section: Introductionmentioning
confidence: 98%
“…Real-time 3-dimensional echocardiography (3DE) using a matrix array transducer enables the acquisition of the full 3D image of the heart and it provides unprecedented information for the quantification of cardiac function. [10] Real-time 3DE precludes the operator dependency and time-consuming acquisition associated with 2-dimensional echocardiography (2DE). It has also been reported to be able to provide accurate and reproducible volume and myocardial strain values comparable with cardiac magnetic resonance (CMR).…”
Section: Introductionmentioning
confidence: 99%