“…The model is adopted from [22] with additional proportional-integral-differential (PID) controller applied to control the input torque to achieve the desired angle of the pendulum. In other words, the same mathematical model in [21] is applied with additional PID controller. The PID controller constants -kP, kI, kD are 0.7, 0.7, and 6.0, respectively.…”