2023
DOI: 10.1021/acs.analchem.2c04231
|View full text |Cite
|
Sign up to set email alerts
|

Reconstruction of Glutathione Metabolism in the Neuronal Model of Rotenone-Induced Neurodegeneration Using Mass Isotopologue Analysis with Hydrophilic Interaction Liquid Chromatography-Zeno High-Resolution Multiple Reaction Monitoring

Abstract: Accurate reconstruction of metabolic pathways is an important prerequisite for interpreting metabolomics changes and understanding the diverse biological processes in disease models. A tracer-based metabolomics strategy utilizes stable isotope-labeled precursors to resolve complex pathways by tracing the labeled atom(s) to downstream metabolites through enzymatic reactions. Isotope enrichment analysis is informative and achieved by counting total labeled atoms and acquiring the mass isotopologue distribution (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 46 publications
0
5
0
Order By: Relevance
“…The mobile phases were composed of (A) 90% acetonitrile in H 2 O with 5 mM ammonium formate and (B) 10% acetonitrile in H 2 O with 5 mM ammonium formate. Chromatographic separation of analytes was carried out with a gradient elution program at a flow rate of 0.5 mL/min. , Electrospray ionization MS was operated in the negative ion mode, and analytes were monitored in the time-of-flight (ToF) mode at a full scan range of 50–900 m / z . , MultiQuant software (AB SCIEX, version 3.0.1) was used in the quantitative analysis for LC-MS raw data extraction and peak area integration. Internal standards were employed to correct random errors during sample preparation.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The mobile phases were composed of (A) 90% acetonitrile in H 2 O with 5 mM ammonium formate and (B) 10% acetonitrile in H 2 O with 5 mM ammonium formate. Chromatographic separation of analytes was carried out with a gradient elution program at a flow rate of 0.5 mL/min. , Electrospray ionization MS was operated in the negative ion mode, and analytes were monitored in the time-of-flight (ToF) mode at a full scan range of 50–900 m / z . , MultiQuant software (AB SCIEX, version 3.0.1) was used in the quantitative analysis for LC-MS raw data extraction and peak area integration. Internal standards were employed to correct random errors during sample preparation.…”
Section: Methodsmentioning
confidence: 99%
“…Chromatographic separation of analytes was carried out with a gradient elution program at a flow rate of 0.5 mL/min. 44 , 45 Electrospray ionization MS was operated in the negative ion mode, and analytes were monitored in the time-of-flight (ToF) mode at a full scan range of 50–900 m / z . 44 , 45 MultiQuant software (AB SCIEX, version 3.0.1) was used in the quantitative analysis for LC-MS raw data extraction and peak area integration.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…14 The utility of the Zeno function for biological applications has recently been demonstrated by Huang et al in a mass isotopologue distribution study on stem cell-derived neurons. 15 Exploiting the scan speed of up to 133 Hz 12 , data-dependent MS2 acquisition can be tailored to ensure high numbers of MS2 spectra upon each sample injection. Additionally, scheduled MS2 was designed and optimized for MRM-like data evaluation.…”
Section: Introductionmentioning
confidence: 99%