2015
DOI: 10.1007/s00595-015-1181-8
|View full text |Cite
|
Sign up to set email alerts
|

Reconstruction using a divided latissimus dorsi muscle flap after conventional posterolateral thoracotomy and the effectiveness of indocyanine green-fluorescence angiography to assess intraoperative blood flow

Abstract: Intraoperative ICG-FA proved extremely useful for assessing altered blood flow of the divided LD and for selecting preserved intercostal perforators.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(13 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…Forty-nine articles, including 1996 surgical flaps, were selected for the review. Study designs included prospective cohort studies (n = 27), 31,34,35,38,39,[41][42][43][47][48][49][50]56,[58][59][60][62][63][64][65][66][67][68][69][70][71] retrospective cohort studies (n = 16), [25][26][27]29,32,33,36,40,44,45,51,55,57,61,72 prospective pilot studies (n = 3), 28,37,52 and retrospective case series (n = 3). 46,53,54 No randomized controlled trials have been performed yet that concern ICGA in plastic and reconstructive flap surgery.…”
Section: Systematic Reviewmentioning
confidence: 99%
“…Forty-nine articles, including 1996 surgical flaps, were selected for the review. Study designs included prospective cohort studies (n = 27), 31,34,35,38,39,[41][42][43][47][48][49][50]56,[58][59][60][62][63][64][65][66][67][68][69][70][71] retrospective cohort studies (n = 16), [25][26][27]29,32,33,36,40,44,45,51,55,57,61,72 prospective pilot studies (n = 3), 28,37,52 and retrospective case series (n = 3). 46,53,54 No randomized controlled trials have been performed yet that concern ICGA in plastic and reconstructive flap surgery.…”
Section: Systematic Reviewmentioning
confidence: 99%
“…Indocyanine green (ICG) is an FDA-approved water-soluble anionic tricarbocyanine dye. As ICG has low toxicity, it is used for various medical examinations, such as the measurement of cardiac output and hepatic function, ophthalmic angiography, and the detection of sentinel lymph nodes (13)(14)(15)(16). In addition, ICG has the properties to act as a near-infrared ray (NIR) photosensitizer for PDT, generating heat and ROS by NIR irradiation (17).…”
Section: Introductionmentioning
confidence: 99%
“…In the described experiments, hand-held imaging systems and microscopes with an integrated NIRF were equally divided for imaging. There were four different hand-held systems (PDE n = 13, Visionsense n = 1, Fluobeam n = 2, and HyperEye n = 1) [ 7 19 , 44 46 , 49 ], one non-hand-held system (FLARE n = 8) [ 36 43 ], and three types of microscopes with an integrated NIRF (SPY n = 16, LEICA n = 2, and Pentero n = 1) [ 20 – 35 , 47 , 48 ] suitable for fluorescence image guidance. In one study, a prototype was used which was not further specified [ 51 ]; three articles unfortunately did not state what kind of imaging system was used [ 52 54 ].…”
Section: Resultsmentioning
confidence: 99%