Red-emissive carbon nanostructure-anchored molecularly imprinted Er-BTC MOF: a biosensor for visual anthrax monitoring

Abstract: Investigating effective fluorescence strategies for real-time monitoring of dipicolinic acid (DPA) is of paramount importance in safeguarding human health. Herein, we present the design of a desirable red emissive carbon...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
5
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 47 publications
1
5
0
Order By: Relevance
“…Additionally, the intrinsic relationship between the DPA concentrations and the luminescence intensities of CuMOF suspensions was investigated. As shown in Figure 7c, it is evident that within the low concentration ranges, there exist favorable linear correlations aligning closely with the equation of I/I 0 = 18,770[DPA] + 1.1254 (K sv = 1.87 Â 10 4 M À1 , R 2 = 0.9675, LOD = 85.2 ng/ml), higher than other reported ones [53][54][55][56][57] (Table 3). Meanwhile, the response time was also conducted, and the results are shown in Figure S12, indicating the luminescence intensity of CuMOF suspensions can be maintained stable after 30 s. Furthermore, the CuMOF exhibits notable antiinterference capabilities when detecting the DPA biomarker amidst the presence of other interfering analytes (Figure S13).…”
Section: Detectability Toward Dpa Biomarkersupporting
confidence: 75%
“…Additionally, the intrinsic relationship between the DPA concentrations and the luminescence intensities of CuMOF suspensions was investigated. As shown in Figure 7c, it is evident that within the low concentration ranges, there exist favorable linear correlations aligning closely with the equation of I/I 0 = 18,770[DPA] + 1.1254 (K sv = 1.87 Â 10 4 M À1 , R 2 = 0.9675, LOD = 85.2 ng/ml), higher than other reported ones [53][54][55][56][57] (Table 3). Meanwhile, the response time was also conducted, and the results are shown in Figure S12, indicating the luminescence intensity of CuMOF suspensions can be maintained stable after 30 s. Furthermore, the CuMOF exhibits notable antiinterference capabilities when detecting the DPA biomarker amidst the presence of other interfering analytes (Figure S13).…”
Section: Detectability Toward Dpa Biomarkersupporting
confidence: 75%
“…6–8 Therefore, accurate measurement of DPA is of the utmost importance to prevent anthrax infection and protect public health. 9…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, to ascertain the binding constant ( K b ) and the quenching efficacy of Fe 3+ ions, Fe 3+ ions, TA, and PO 4 3– ions upon interaction with CPD1, CPD2, CPD2, and CPD3, respectively, the formula log­( F 0 – F / F ) = log K b + n log­[Q] was utilized. Here, n denotes the number of interacting sites, [Q] signifies the quencher’s concentration, F 0 represents the fluorescence intensity without the quencher, and F is the fluorescence intensity in the quencher’s presence . The computed K b values were established as 2.81 1/mM, 2.69 1/mM, 4.26 1/mM, and 2.63 1/mM for Fe 3+ ions, Fe 3+ ions, TA, and PO 4 3– ions, respectively (Figure S8c,g,k,o).…”
Section: Resultsmentioning
confidence: 98%
“…Herein, we introduce a highly portable four-channel skin-interfaced soft microfluidic device that allows simultaneous sweat sampling and fluorometric sensing of potential kidney disease biomarkers including l -Tyr, l -Trp, Crt, and NH 4 + . The as-design device seamlessly integrates with smartphones, enabling convenient data retrieval and analysis . The sensing array utilizes a novel fluorometric solid-state mechanism with CPDs derived from dopamine, catechol, and o -phenylenediamine monomers embedded in the gelatin hydrogel.…”
Section: Introductionmentioning
confidence: 99%