“…However, as the dimensions of patterned space increases from 11 mm to 26 and 41 mm, the radiation heat flux over the glass interior surface will raise to 160 and 163 W/m 2 , respectively. Therefore, based on results provided in Figure 4, enlarging the patterned space will yield the increase in the radiation heat flux on the glass surface, and this analytical result is supported by experimental measurements given by Lin et al 1 Furthermore, the variation of CFD-determined results based on different mesh/ grid dimensions is analyzed. For the roof trapezoidal patterned glass of Figure 3 having 45°-patterned angle and 11-mm-patterned spacing, the CFD model meshed by sizes of 3.5, 3, and 2.5 mm gives the radiation heat fluxes on the inner face of glass equal to 154, 156, and 155.84 W/m 2 , respectively.…”