2014 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC) 2014
DOI: 10.1109/ropec.2014.7036312
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of stray losses in Tertiary Voltage Bushings in power transformer tanks

Abstract: This paper presents an analysis and computation of stray losses in the tank cover of a 75 MVA three-phase coretype transformer. Stray losses in the region surrounding high current bushings are estimated using 3D Finite Element (FE) simulations. In the considered region the stray losses are high and its reduction is important to avoid the presence of hot spots in the tank cover of power transformer. In this paper, an L-shape non-magnetic Stainless Steel Insert (SSI) is utilized to reduce the stray losses in the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 15 publications
0
1
0
1
Order By: Relevance
“…3.1 Hasil pengukuran. Uji kerugian pada beban (Load Losses) [8] untuk mengetahui seberapa besar kerugian tembaga I 2 R pada saat dibebani arus nominal dan kerugian tambahan (stray losses) [9] pada belitan struktur transformator akibat kebocoran flux [2] di pengujian ini dan disebut juga dengan pengujian rangkaian tertutup (short circuit). Untuk mengetahui stray losses (kerugian tambahan) didapat pada pengujian hubung singkat (short circuit), didalam persamaan dituliskan sebagai berikut: : Rugi-rugi pada struktur tangki dan belitan akibat kebocoran medan magnet.…”
Section: Hasil Dan Pembahasanunclassified
“…3.1 Hasil pengukuran. Uji kerugian pada beban (Load Losses) [8] untuk mengetahui seberapa besar kerugian tembaga I 2 R pada saat dibebani arus nominal dan kerugian tambahan (stray losses) [9] pada belitan struktur transformator akibat kebocoran flux [2] di pengujian ini dan disebut juga dengan pengujian rangkaian tertutup (short circuit). Untuk mengetahui stray losses (kerugian tambahan) didapat pada pengujian hubung singkat (short circuit), didalam persamaan dituliskan sebagai berikut: : Rugi-rugi pada struktur tangki dan belitan akibat kebocoran medan magnet.…”
Section: Hasil Dan Pembahasanunclassified
“…The orientation of the shunt also plays an important role in reducing losses, which is why works such as [18] clearly and conclusively confirm the effectiveness of orienting the shunt horizontally. In [19] non-magnetic stainless steel, an insert was utilized to reduce the stray losses in a significant way in 80% of the region of the Tertiary Voltage Bushings of the transformer. The effect of magnetic shunts on shelltype transformers' characteristics was recently analysed and determined.…”
Section: Introductionmentioning
confidence: 99%