2017 19th European Conference on Power Electronics and Applications (EPE'17 ECCE Europe) 2017
DOI: 10.23919/epe17ecceeurope.2017.8099384
|View full text |Cite
|
Sign up to set email alerts
|

Reduction of voltage and power oscillation in the two-phase shorting of a grid inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…To control the active and reactive power at the output of the converter, correct and reliable synchronisation with the distribution grid is required (Blaabjerg et al, 2006). For the purpose of synchronization, it has been proposed to use the DDSRF-PLL algorithm (Jarzyna, 2019;Jarzyna et al, 2020;Nicastri and Nagliero, 2010;Rodriguez et al, 2007;Silva et al, 2004), which operates on the basis of feedback, thereby ensuring that it is able to provide a synchronisation signal with high quality parameters even in case of strong disturbances occurring in the utility grid (Jarzyna et al, 2017). A sawtooth synchronisation signal assuming values in the range <0, 2π> is converted into a sine wave reference signal of amplitude 1.…”
Section: Four-wire Hybrid Converter With Multi-resonant Regulatorsmentioning
confidence: 99%
“…To control the active and reactive power at the output of the converter, correct and reliable synchronisation with the distribution grid is required (Blaabjerg et al, 2006). For the purpose of synchronization, it has been proposed to use the DDSRF-PLL algorithm (Jarzyna, 2019;Jarzyna et al, 2020;Nicastri and Nagliero, 2010;Rodriguez et al, 2007;Silva et al, 2004), which operates on the basis of feedback, thereby ensuring that it is able to provide a synchronisation signal with high quality parameters even in case of strong disturbances occurring in the utility grid (Jarzyna et al, 2017). A sawtooth synchronisation signal assuming values in the range <0, 2π> is converted into a sine wave reference signal of amplitude 1.…”
Section: Four-wire Hybrid Converter With Multi-resonant Regulatorsmentioning
confidence: 99%
“…Most works are focusing on synchronization in the UG in stable conditions, but this may not always be true. Articles [6]- [8] and [26] address the problems with the synchronization of converters in the case of disturbances in the UG.…”
Section: Active Synchronizationmentioning
confidence: 99%
“…For that reason the SRF PLL algorithm can be easily extended to any other synchronization algorithm suitable to synchronize the MG with the UG when such disturbances occur. Articles [6][7][8] and [26], [40] address problems with synchronization of converters in the case of such events on the MG or UG side.…”
Section: Synchronization Data Exchange Algoritmsmentioning
confidence: 99%
See 1 more Smart Citation
“…The correct operation of inverters depends mainly on their topology but also on the control method. Hence, more and more works aim to optimize the inverters used in electric drive, grid [11,12], renewable energy [13], and electromobility [14,15] applications. The damage possibility caused by excessive heating of the device [16] has also led to the development of numerous techniques to estimate the temperature of both BLDC motors [17] and semiconductor junctions of transistors.…”
Section: Introductionmentioning