2015
DOI: 10.1159/000438450
|View full text |Cite
|
Sign up to set email alerts
|

Reference Ranges for Cerebral Tissue Oxygen Saturation Index in Term Neonates during Immediate Neonatal Transition after Birth

Abstract: Background: Non-invasive monitoring of the brain with near-infrared spectroscopy (NIRS) during immediate transition after birth is of growing interest. Objective: The aim of this work was to define reference ranges and centile charts for a regional cerebral tissue oxygenation index (cTOI), measured with the NIRO 200NX (NIRO, Hamamatsu, Japan), and cerebral fractional tissue oxygen extraction (cFTOE) during the first 15 min after birth in preterm and term neonates without any medical support. Methods: cTOI was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
46
1
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 79 publications
(55 citation statements)
references
References 11 publications
6
46
1
2
Order By: Relevance
“…rScO 2 is between approximately 40 and 56% directly after birth (irrespective of delivery mode) (4143), increases up to 78% in the first 2 days after birth (44) and then slowly stabilizes during 3–6 weeks after birth with values between 55 and 85% (4547). Several studies have published reference ranges immediately after birth, which show a gradual increase during the first 15 min of life (42, 46).…”
Section: Introductionmentioning
confidence: 99%
“…rScO 2 is between approximately 40 and 56% directly after birth (irrespective of delivery mode) (4143), increases up to 78% in the first 2 days after birth (44) and then slowly stabilizes during 3–6 weeks after birth with values between 55 and 85% (4547). Several studies have published reference ranges immediately after birth, which show a gradual increase during the first 15 min of life (42, 46).…”
Section: Introductionmentioning
confidence: 99%
“…In our institution, due to the possibility of a multidisciplinary use, such as in cardiac and vascular surgery, orthopedic surgery, abdominal surgery, neonatal, and pediatric intensive care units, the monitoring device supplied is the Somanetics INVOS 5100C Cerebral/Somatic Oximeter (Covidien). [32][33][34][35] However, the most used device in flap monitoring is ViOptix. 13,14 Like ViOptix, also Somanetics INVOS 5100C Cerebral/Somatic Oximeter provides instantaneous value continuously, and allows the possibility to set the warning threshold value.…”
Section: Discussionmentioning
confidence: 99%
“…Although the use of multiple devices monitoring resuscitation (pulse oximetry, ECG, respiratory function monitor-RFM, end-tidal CO 2, NIRS) is still challenging in the DR, there is an increasing interest in monitoring physiologic changes during neonatal transition [59][60][61][62].…”
Section: Monitoring During Neonatal Transitionmentioning
confidence: 99%