1974
DOI: 10.1063/1.3253149
|View full text |Cite
|
Sign up to set email alerts
|

Reference Wavelengths From Atomic Spectra in the Range 15 Å to 25000 Å

Abstract: This is a compilation of atomic lines with accurately known wavelengths covering the range from 15 Å to 25000 Å. The tables are a fairly complete record of available spectrum lines that meet the requirements for useful references with regard to wavelength accuracy and intensity. In general, wavelength uncertainties range from 0.0001 Å to 0.002 Å. Section 1, λ > 2000 Å, gives λair and λvac for 3341 lines belonging to thirteen different spectra of ten elements. Section 2, λ < 2000 Å, contains 2091 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
88
0

Year Published

1996
1996
2020
2020

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 301 publications
(90 citation statements)
references
References 0 publications
2
88
0
Order By: Relevance
“…All gases and chemicals were research grade and were used without further purification. The wavenumber scale of the spectrometer was calibrated by use of Ne I or Ar I reference lines (17). In the medium-resolution measurements reported here, the precision of the measured wavenumbers is on the order of 0.1 cm Ϫ1 .…”
Section: Methodsmentioning
confidence: 99%
“…All gases and chemicals were research grade and were used without further purification. The wavenumber scale of the spectrometer was calibrated by use of Ne I or Ar I reference lines (17). In the medium-resolution measurements reported here, the precision of the measured wavenumbers is on the order of 0.1 cm Ϫ1 .…”
Section: Methodsmentioning
confidence: 99%
“…Under Ref., 1 is for Musiol et al (1988) and 2. for Jones & Miller (1974). Kaufman & Edlén (1974). The comparison of semiclassical method of Griem et al (1962) (see also Griem 1974), used in Dimitrijević & Konjević (1983) and the semiclassical perturbation method (Sahal-Bréchot 1969a,b) used here, as well as an explanation of the differences, is given in Dimitrijević & Sahal-Bréchot (1996).…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, in the present experiments it could not be decided whether the observed species are formed and excited in the discharge or by chemical reactions in the flowing afterglow. The wavenumber scale of the spectrometer was calibrated by use of emission lines of argon as standards (26). The absolute accuracy of the measurements is thought to be better than 0.01 cm −1 and the relative precision of the wavenumbers of strong lines is on the order of 10 −4 cm −1 .…”
Section: Methodsmentioning
confidence: 99%