1986
DOI: 10.1002/app.1986.070310726
|View full text |Cite
|
Sign up to set email alerts
|

Relationship between phenolic adhesive chemistry and adhesive joint performance: Effect of filler type on fraction energy

Abstract: synopsisThe performance of adhesive bonded joints depends on many factors, one of which is the adhesive formulation. The effects of organic and inorganic fillers upon the fracture toughness of phenol-resorcinol-formaldehyde adhesive in hard maple joints were explored in this study. Analytical techniques (DSC, IR, SEM, and GPC), and solubility studies were employed to relate physical effects to chemical effects of the fillers. The resin showed two distinct stages of cure: (1) a low temperature exotherm associat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

1991
1991
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(23 citation statements)
references
References 6 publications
0
23
0
Order By: Relevance
“…The assignment of characteristic peaks was done on the basis of the relevant literature. [23][24][25][26] The spectra in the wave number range of interest for the TMeP synthesis at 60°C are presented in Figure 2. They were collected every 3 min at a resolution of 8 cm…”
Section: Tmep Synthesismentioning
confidence: 99%
“…The assignment of characteristic peaks was done on the basis of the relevant literature. [23][24][25][26] The spectra in the wave number range of interest for the TMeP synthesis at 60°C are presented in Figure 2. They were collected every 3 min at a resolution of 8 cm…”
Section: Tmep Synthesismentioning
confidence: 99%
“…Ebewele et al 3 have examined the effects of various inorganic and organic fillers on the properties of phenol-resorcinol-formaldehyde adhesives. It was reported that these fillers had no effect on adhesive cure; however, the use of the filled adhesives showed a pronounced effect on the morphology of the woodadhesive interphase and on the bulk adhesive properties.…”
Section: Introductionmentioning
confidence: 99%
“…In wood science, the measurement of G c with a DCB configuration was mainly employed to evaluate wood adhesive performances, or wood properties. [33][34][35][36][37][38][39] A symmetric DCB configuration was often employed in these analyses and samples were fractured toward an opening-mode I loading test. Consequently, the mechanics at the interface and the sample geometry were first studied in this manner.…”
Section: Resultsmentioning
confidence: 99%