2015
DOI: 10.1055/s-0034-1399096
|View full text |Cite
|
Sign up to set email alerts
|

Reliabilität ausgewählter Parameter der Fahrradergospirometrie anhand des PowerCube-Ergo-Atemgasanalysators

Abstract: This study aimed to investigate the reliability of 1) the key parameters of cycling ergospirometry (maximum power output [Pmax] and oxygen uptake [V̇O2peak], ventilatory thresholds 1 [VT 1] and 2 [VT 2], and cycling efficiency [CE] and gross efficiency [GE]), 2) the commonly used parameters to quantify exhaustion (maximum heart rate [HFmax], respiratory quotient [RQmax], blood lactate concentration [BLAmax], and ratings of perceived exhaustion [RPEmax]), and 3) the kinetics of exercise induced gas exchange mea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 26 publications
0
4
0
Order By: Relevance
“…Immediately after reaching exhaustion, capillary blood was taken from the participant's earlobe to be analysed by an electro-enzymatic analyser (EKF-diagnostics, Biosen C_line Sport, Cardiff, United Kingdom) for the lactate concentration. The reliability of the stationary and mobile cycling ergometer, and gas and lactate analyser is CV = 8.2% ( 42 ), CV = 2.3% ( 43 ), ICC = 0.991–0.995 ( 44 ), and CV = 1.3% ( 45 ), respectively.…”
Section: Methodsmentioning
confidence: 97%
“…Immediately after reaching exhaustion, capillary blood was taken from the participant's earlobe to be analysed by an electro-enzymatic analyser (EKF-diagnostics, Biosen C_line Sport, Cardiff, United Kingdom) for the lactate concentration. The reliability of the stationary and mobile cycling ergometer, and gas and lactate analyser is CV = 8.2% ( 42 ), CV = 2.3% ( 43 ), ICC = 0.991–0.995 ( 44 ), and CV = 1.3% ( 45 ), respectively.…”
Section: Methodsmentioning
confidence: 97%
“…The samples were analyzed by an electro-enzymatic analyzer (EKF-diagnostics, Biosen C_line Sport, London, United Kingdom). The reliability of the cycling ergometer, gas analyzer, and electro-enzymatic analyzer was reported by a coefficient of variation (CV) = 8.2% [ 34 ], intraclass coefficient (ICC) = 0.991–0.995 [ 35 ], and CV = 1.3% [ 36 ], respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The anaerobic threshold was determined using the V-slope method. 41 The submaximal load was determined as the second last completed incremental. VO 2peak was defined as the highest VO 2 observed during testing.…”
Section: Methodsmentioning
confidence: 99%