Reliability of 3-m Backward Walk Test in Patients with Primary Total Knee Arthroplasty

Abstract: The 3-m backward walk test (3MBWT) is used to evaluate neuromuscular control, proprioception, protective reflexes, fall risk, and balance. The aim of the present study was to determine the test–retest reliability of the 3MBWT in patients with primary total knee arthroplasty (TKA). Twenty-eight patients with primary TKA, operated by the same surgeon, were included in this study. Patients performed trials for 3MBWT twice on the same day. Between the first and second trials, patients waited for an hour on sitting… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 19 publications
0
14
0
Order By: Relevance
“…Advances in technology have allowed the incorporation of sensor-based systems to provide standardized clinical data to help the design of tailored interventions 15 . The available studies on patients with TKR have focused on designing balance-oriented interventions; 9 , 16 18 describing patients’ clinical and demographic characteristics 19 , 20 ; identifying risk factors; 21 23 developing and validating clinical tests to assess fall risk; 24 26 and characterizing the biomechanics of postural control strategies to recognize potential fallers 27 , 28 . Some studies have also paid attention to characterizing patients and circumstances surrounding fall events.…”
Section: Introductionmentioning
confidence: 99%
“…Advances in technology have allowed the incorporation of sensor-based systems to provide standardized clinical data to help the design of tailored interventions 15 . The available studies on patients with TKR have focused on designing balance-oriented interventions; 9 , 16 18 describing patients’ clinical and demographic characteristics 19 , 20 ; identifying risk factors; 21 23 developing and validating clinical tests to assess fall risk; 24 26 and characterizing the biomechanics of postural control strategies to recognize potential fallers 27 , 28 . Some studies have also paid attention to characterizing patients and circumstances surrounding fall events.…”
Section: Introductionmentioning
confidence: 99%
“…The reliability of walking tests was reported in 10 “adequate” quality studies 19,20,27–29,3539 and three “doubtful” quality studies. 25,40,41 “Sufficient” result ratings were reported in 2-min fast-paced walk test (intraclass correlation coefficient (ICC) 0.97), 28 walk 40 m fast-paced (ICC 0.85–0.98), 20,35,36 walk 4 m fast-paced (ICC 0.84–0.93), 25 30 min fast-paced walk (ICC 0.97), 27 3-m backward walking at fast speed (ICC 0.94), 37 walk 13 m self-paced (ICC 0.80–0.98), 38,39 walk 4 m self-paced (ICC 0.79–0.87), 25 2 min step test (ICC 0.94–0.97), 29 and 2 min normal-paced walk test (ICC 0.98). 19 For CSTs, “sufficient” ratings were reported for test–retest reliability on chair-rise over 30 s (ICC 0.87–0.98), 20,35,36 TUG (ICC 0.98) 28 in four “adequate” studies, and L test in one “adequate” study (ICC 0.99), 42 and for inter/intrarater reliability on GUG (ICC 0.95–0.98) 43 in one “doubtful” quality study.…”
Section: Resultsmentioning
confidence: 99%
“…The reliability of walking tests was reported in 10 "adequate" quality studies 19,20,[27][28][29][35][36][37][38][39] and three "doubtful" quality studies. 25,40,41 "Sufficient" result ratings were reported in 2-min fast-paced walk test (intraclass correlation coefficient (ICC) 0.97), 28 walk 40 m fast-paced (ICC 0.85-0.98), 20,35,36 walk 4 m fast-paced (ICC 0.84-0.93), 25 30 min fast-paced walk (ICC 0.97), 27 3-m backward walking at fast speed (ICC 0.94), 37 walk 13 m self-paced (ICC 0.80-0.98), 38,39 walk 4 m self-paced (ICC 0.79-0.87), 25 2 min step test (ICC 0.94-0.97), 29 and 2 min normal-paced walk test (ICC 0.98). 19 For CSTs, "sufficient" ratings were reported for testretest reliability on chair-rise over 30 s (ICC 0.87-0.98), 20,35,36 TUG (ICC 0.98) 28 in four "adequate" No hypothesis defined (by the review team)…”
Section: Measurement Propertiesmentioning
confidence: 99%
“…The excellent test-retest reliability of the BWT found in this study (ICC = 0.96) is consistent with the findings in a previous study on older adults who had undergone knee surgery (ICC = 0.94). 2 This study is the first to examine the interrater reliability of the BWT in any population. The high reliability might be attributable to the use of the standardized protocol of the BWT.…”
Section: Discussionmentioning
confidence: 99%
“…Strong test-retest reliability of the BWT has been previously reported in people with total knee arthroplasty-intraclass correlation coefficient (ICC) = 0.97. 2 We expected that a sample size of 30 would be required to achieve 90% power at a confidence level of 0.05 to detect a strong reliability (ICC ≥ 0.90). Anticipating a 20% dropout rate, this study aimed to recruit 38 participants.…”
Section: Sample Size Calculationmentioning
confidence: 99%