2012
DOI: 10.1186/1743-0003-9-37
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of movement workspace measurements in a passive arm orthosis used in spinal cord injury rehabilitation

Abstract: BackgroundRobotic and non-robotic training devices are increasingly being used in the rehabilitation of upper limb function in subjects with neurological disorders. As well as being used for training such devices can also provide ongoing assessments during the training sessions. Therefore, it is mandatory to understand the reliability and validity of such measurements when used in a clinical setting. The aim of this study was to evaluate the reliability of movement measures as assessed in the Armeo Spring syst… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(26 citation statements)
references
References 27 publications
0
26
0
Order By: Relevance
“…In particular, cortical reorganization and associated functional motor recovery, key factors in neurologic rehabilitation (Rudhe et al, 2012), after virtual reality in patients with chronic stroke are documented also by fMRI (Jang et al, 2005). In addition, these devices are able to support the patient's arm weight during therapy (O'Dell et al, 2009), thus allowing individuals unable to lift their arm sufficiently against gravity to be treated.…”
Section: Introductionmentioning
confidence: 99%
“…In particular, cortical reorganization and associated functional motor recovery, key factors in neurologic rehabilitation (Rudhe et al, 2012), after virtual reality in patients with chronic stroke are documented also by fMRI (Jang et al, 2005). In addition, these devices are able to support the patient's arm weight during therapy (O'Dell et al, 2009), thus allowing individuals unable to lift their arm sufficiently against gravity to be treated.…”
Section: Introductionmentioning
confidence: 99%
“…As well as being used for training such devices can also provide ongoing assessments during the training sessions. Therefore, it is mandatory to understand the reliability and validity of such measurements when used in a clinical setting [13]. We consent, therefore, started using non-robotic Armeo ® equipment in our rehabilitation center.…”
Section: Discussionmentioning
confidence: 99%
“…Also, positioning of the subject in the device is a potential reliability limitation. Previous work with the same device in a nonburn population demonstrated reliable tracking of movements with different seating positions [17]; this issue was mitigated by use of a consistent positioning protocol consistent with manufacturer recommendations. Lastly, this feasibility study did not include detailed information of the burn injury (ie, time since burn, duration of hospital stay, location, type, and number of surgeries) as this was considered outside the scope of the study design; future studies of efficacy should consider including additional burn related data.…”
Section: Discussionmentioning
confidence: 99%
“…The system is an adjustable arm orthosis with demonstrated feasibility in the stroke [14], spinal cord injury [15], and multiple sclerosis [16] populations. Previous research has demonstrated reliability of the system in a nonburn population [17]. When using the system, one's upper extremity is fit onto the device with Velcro straps at the forearm and upper arm ( Figure 1).…”
Section: Gaming Systemmentioning
confidence: 99%