1994
DOI: 10.1080/15428119491018411
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of Respiratory Inductive Plethysmography for Measuring Tidal Volume During Exercise

Abstract: This study was designed to determine the reliability of measurements of respiratory volumes obtained with a respiratory inductive plethysmograph (RIP) during exercise. Tidal volumes (VT) from the RIP were compared with simultaneous flowmeter volumes in 8 healthy subjects at 5 incremental work rates of 60, 90, 120, 150, and 180 W during cycling and treadmill exercise. During cycling, average RIP and flowmeter values did not differ significantly at work rates below 180 W for 63% of the subjects. Average RIP and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
28
0

Year Published

1998
1998
2016
2016

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(28 citation statements)
references
References 0 publications
0
28
0
Order By: Relevance
“…8 Moreover, respiratory inductive plethysmography is a reliable tool to measure ventilation during exercise. 11,36 Hence, we believe that the use of Respitrace in the present study allows us to estimate abdominal muscle work during exercise.…”
Section: Discussionmentioning
confidence: 97%
“…8 Moreover, respiratory inductive plethysmography is a reliable tool to measure ventilation during exercise. 11,36 Hence, we believe that the use of Respitrace in the present study allows us to estimate abdominal muscle work during exercise.…”
Section: Discussionmentioning
confidence: 97%
“…We defined 100% VT to be the average volume of chest and abdominal motion during the initial 5-minutes calibration period at rest in the sitting position on a bicycle ergometer. The accuracy of this device has been previously reported 11) . The analog data of TV and thoracoabdominal motion were input into a personal computer, and synchronized with a software program (Biopack System Inc, San Diego, CA) as shown in Fig.…”
Section: Methodsmentioning
confidence: 81%
“…(14) Limitations of our study include the relatively small sample size (10 subjects) that may have been too undersized to detect a true difference (β-error) between the two test systems, although other LifeShirt studies have utilized similar numbers and achieved statistical significance. (4) Also, although we tested our subjects at 50%V O 2max , firefighters often have short bursts of activity at much higher levels, and a prior comparison of the LifeShirt and pneumotachograph noted that discrepancies inV E between the two systems grow larger with increasing exercise intensity. (17) Therefore, it is theoretically possible that had we employed a greater workload in the study, we might have noted greater variance inV E measurements between the two systems.…”
Section: Discussionmentioning
confidence: 98%
“…Physiological data monitored by wearable plethysmographic sensors vests are usually stored onto a small, portable data recorder carried in a pouch attached to the vest and telemetered in real-time to a laptop computer. The wearable plethysmographic sensors vests have been used in research under high gravitational force environments, (3) with exercise, (4) and at rest with resistive loads. (5) These studies evaluated the system under different conditions, but they were not a comparison study wearing firefighting ensembles.…”
Section: Introductionmentioning
confidence: 99%