2016
DOI: 10.1007/s10840-016-0197-3
|View full text |Cite
|
Sign up to set email alerts
|

Remote magnetic navigation for ventricular ablation: did the machine win this round?

Abstract: Remote magnetic navigation has been available as a tool for mapping and ablation for well over a decade. In that period of time, it has shown to be useful in nearly every type of ablation procedure from the most simple to the most complex [1][2][3]. Some operators prefer the system for atrial fibrillation ablation, others for ventricular tachycardia ablation, and some use it for any ablation. Despite numerous publications showing reductions in fluoroscopic exposure and the obvious benefits of not wearing lead … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…2B), and each has limited independence in position and orientation control. In a recent editorial, J. Burkhart pointed out that one of the main limitations of remote magnetic navigation is the limited variety of magnetic catheters [15].…”
Section: Design and Evaluation Of A Steerable Magnetic Sheath For Car...mentioning
confidence: 99%
“…2B), and each has limited independence in position and orientation control. In a recent editorial, J. Burkhart pointed out that one of the main limitations of remote magnetic navigation is the limited variety of magnetic catheters [15].…”
Section: Design and Evaluation Of A Steerable Magnetic Sheath For Car...mentioning
confidence: 99%
“…RMN was associated with higher signal shrinkage with a mean positive figure in comparison to CF‐guided ablation. Catheter stability is higher in RMN for both acquisition and ablation . The trade‐off is a decrease in maximal force applied, which although creates a smaller more homogenous lesion, may lead to only partial isolation, especially when more anatomically complex lesions are involved .…”
mentioning
confidence: 99%
“…Furthermore, when undergoing catheter ablation for ventricular arrhythmias, mapping via RMN tends to demonstrate less distortion and produce a more accurate representation of the targeted chamber . A more uniform and constant contact likely leads to more homogenous lesions . In a meta‐analysis of studies of ventricular tachycardia ablation, RMN was associated with significantly lower ventricular tachycardia recurrence as well as procedural adverse events compared to manually guided ablation …”
mentioning
confidence: 99%