Removal of toluene in waste gases using a biological trickling filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
30
0
1

Year Published

1997
1997
2009
2009

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 62 publications
(34 citation statements)
references
References 6 publications
3
30
0
1
Order By: Relevance
“…Removal capacities of the same magnitude were found by other researchers studing toluene removal from waste gases in laboratory trickling filters (Wolff 1992;Schindler et al 1994 andPedersen &Arvin 1995). Shareefdeen & Baltzis (1994) recently proved that a laboratory biofilter, modelled both for steadystate and transient operations, was capable of achieving 100% removal of toluene, given enough residence time.…”
Section: Biofilter Efficiency In Toluene Removalsupporting
confidence: 53%
“…Removal capacities of the same magnitude were found by other researchers studing toluene removal from waste gases in laboratory trickling filters (Wolff 1992;Schindler et al 1994 andPedersen &Arvin 1995). Shareefdeen & Baltzis (1994) recently proved that a laboratory biofilter, modelled both for steadystate and transient operations, was capable of achieving 100% removal of toluene, given enough residence time.…”
Section: Biofilter Efficiency In Toluene Removalsupporting
confidence: 53%
“…Some studies have shown that the flow rate of the trickling phase may affect the overall reactor's performance under certain conditions. In studies undertaken with pollutants as toluene, 75 mono-chlorobenzene, 76 and dichloromethane, 15,17 it has been recommended to apply a high superficial liquid flow rate (L), which will result in a low G/L ratio. This would ensure a high degree of wetting, resulting in a high reactor's performance.…”
Section: Characteristics Of the Trickling Liquid Phase And The Gas Phasementioning
confidence: 99%
“…The observed slope (0.31) was only a little higher than the Henry's constant, indicating that the system was close to equilibrium at the gas effluent of the column. Therefore, mass transfer had little influence on the elimination capacity (Pedersen and Arvin, 1995).…”
Section: Elimination Of Toluenementioning
confidence: 99%
“…The inoculum originated from a creosote-polluted sandy aquifer (Fredensborg, Denmark) and was collected from an earlier experiment in which a trickling filter treating toluene was studied (Pedersen and Arvin, 1995). A sample of the (1) gas flow meter; (2) integrator (Shimadzu C-R3A Chromatopac); (3) gas chromatograph (Shimadzu GC-14A); (4) 2-points valve and 8-points valve (Valco Instruments Co. Inc.) for gas sampling; (5) filter column; (6) gas mixing coil; (7) membrane pump for air supply; (8) peristaltic pump; (9) pure toluene flask; (10) liquid container; (11) recirculation pump.…”
Section: Inoculation Of Biofilm Reactormentioning
confidence: 99%