2014
DOI: 10.1158/1078-0432.ccr-13-2634
|View full text |Cite
|
Sign up to set email alerts
|

Repeatability of Quantitative FDG-PET/CT and Contrast-Enhanced CT in Recurrent Ovarian Carcinoma: Test–Retest Measurements for Tumor FDG Uptake, Diameter, and Volume

Abstract: Purpose: Repeatability of baseline FDG-PET/CT measurements has not been tested in ovarian cancer. This dual-center, prospective study assessed variation in tumor 2[18F]fluoro-2-deoxy-D-glucose (FDG) uptake, tumor diameter, and tumor volume from sequential FDG-PET/CT and contrast-enhanced computed tomography (CECT) in patients with recurrent platinum-sensitive ovarian cancer.Experimental Design: Patients underwent two pretreatment baseline FDG-PET/CT (n ¼ 21) and CECT (n ¼ 20) at two clinical sites with differe… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
29
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 39 publications
(32 citation statements)
references
References 24 publications
3
29
0
Order By: Relevance
“…Table 1 shows the articles that were identified and included in this review. Sixteen papers (20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35), published between 1995 and 2016, met the inclusion criteria. All were reports on original research, although there was some overlap in the source data: Nakamoto et al (22) (28) performed a metaanalysis pooling data from 5 previously published cohorts.…”
Section: Suv Repeatability Literaturementioning
confidence: 99%
See 4 more Smart Citations
“…Table 1 shows the articles that were identified and included in this review. Sixteen papers (20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33)(34)(35), published between 1995 and 2016, met the inclusion criteria. All were reports on original research, although there was some overlap in the source data: Nakamoto et al (22) (28) performed a metaanalysis pooling data from 5 previously published cohorts.…”
Section: Suv Repeatability Literaturementioning
confidence: 99%
“…Each of these studies involved a careful test-retest protocol with two repeated imaging sessions using the same protocol and scanner system for each patient. Four of the publications (25,(31)(32)(33) included data acquired at multiple centers, although, to be clear, individual patients were always scanned on the same system. The remaining reports were on single-center studies.…”
Section: Data Acquisitionmentioning
confidence: 99%
See 3 more Smart Citations