2016
DOI: 10.3349/ymj.2016.57.6.1339
|View full text |Cite
|
Sign up to set email alerts
|

Repolarization Heterogeneity of Magnetocardiography Predicts Long-Term Prognosis in Patients with Acute Myocardial Infarction

Abstract: PurposeMagnetocardiography (MCG) has been proposed as a noninvasive, diagnostic tool for risk-stratifying patients with acute myocardial infarction (AMI). This study evaluated whether MCG predicts long-term prognosis in AMI.Materials and MethodsIn 124 AMI patients (95 males, mean age 60±11 years), including 39 with ST-elevation myocardial infarction, a 64-channel MCG was performed within 2 days after AMI. During a mean follow-up period of 6.1 years, major adverse cardiac events (MACE) were evaluated.ResultsMAC… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
7
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 21 publications
1
7
0
Order By: Relevance
“…Although there is no clear standardization for MCG to diagnose CAD. Several MCG parameters calculated along the ST interval and T-wave were typically abnormal at rest in patients with CAD, and appear to be sensitive diagnostic parameters (3,5,6,11,(15)(16)(17).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Although there is no clear standardization for MCG to diagnose CAD. Several MCG parameters calculated along the ST interval and T-wave were typically abnormal at rest in patients with CAD, and appear to be sensitive diagnostic parameters (3,5,6,11,(15)(16)(17).…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, artefacts from unreliable and/or fluctuating electrode-skin contacts, such as in practical ECG, cannot occur (1). Recently, it has been reported that MCG has shown high performance in diagnosing coronary artery disease (CAD) (3)(4)(5)(6). Typical parameters useful for CAD diagnosis were current angle, field map angle, pole distance, QTc dispersion and non-dipolar phenomenon in the magnetic field maps (MFMs) (5)(6)(7).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…VR analysis is considered one of the most useful applications of MCG, mainly to recognize ischemic, inflammatory, or degenerative abnormalities (Tavarozzi, Comani, Del Gratta, Di Luzio et al., ). However, although some attempts to assess the reproducibility and comparability of MCG parameters gathered with different instrumentations have been reported (Burghoff, Nenonen, Trahms, & Katila, ; Nalbach et al., ; Pesola et al., ; Smith et al., ; Takala et al., ), a standardization adequate for clinical application is still missing, especially taking into account the potential source of error due to different S/Nr and/or sequential data acquisition (Bang et al., ; Hänninen et al., ; Kawakami et al., ; Mäkijärvi et al., ; Shin et al., ) as occurs with most instrumentations for unshielded MCG (Fenici, Brisinda, & Meloni, ; Leder et al., ) due to their limited number of sensors.…”
Section: Discussionmentioning
confidence: 99%
“…The authors report on the association of non-dipole patterns at T-peak in resting magnetocardiography (MCG) and major adverse cardiac event (MACE), including composite of death from any cause, reinfarction, and percutaneous coronary intervention, during the follow-up period (mean 6.1 years) in 124 patients with acute coronary syndromes (ACS) 1. In multivariate analysis, patients with non-dipole patterns at T-peak showed increased hazard ratios for MACE ( p =0.02) and lower cumulative MACE-free survival than those with dipole patterns ( p =0.02).…”
mentioning
confidence: 99%