2009
DOI: 10.1093/ejechocard/jep188
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility in echocardiographic assessment of the left ventricular global and regional function, the HUNT study

Abstract: Systolic M-mode annulus excursion showed better inter-observer reproducibility than other traditional and newer measurements of LV systolic and diastolic function. Repeated analyses of the same recordings underestimate the more clinically relevant inter-observer reproducibility by approximately 40% for most measurements of LV function.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

13
97
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 117 publications
(111 citation statements)
references
References 25 publications
13
97
1
Order By: Relevance
“…In spite of the high reliability of both techniques per se, we have shown a relatively poor correlation between them. This result is consistent with recent reports in adulthood [42,43] demonstrating a low correlation among deformation measurements which supports the notion that TDI and 2D-strain cannot be interchanged. Similarly, strain and strain rate values obtained from different ultrasound equipments or software may yield variable results which cannot be directly compared [43].…”
Section: Discussionsupporting
confidence: 93%
“…In spite of the high reliability of both techniques per se, we have shown a relatively poor correlation between them. This result is consistent with recent reports in adulthood [42,43] demonstrating a low correlation among deformation measurements which supports the notion that TDI and 2D-strain cannot be interchanged. Similarly, strain and strain rate values obtained from different ultrasound equipments or software may yield variable results which cannot be directly compared [43].…”
Section: Discussionsupporting
confidence: 93%
“…The corresponding COR was significantly higher in single-wall analyses and significantly lower in similar analyses performed on the same echocardiograms. 16 Thus, all presented analyses show clinically acceptable reproducibility.…”
Section: Comparison Of Methodsmentioning
confidence: 60%
“…12,16 One experienced physician-echocardiographer (H.D.) performed all analyses according to the ASE/EAE recommendations.…”
Section: Analysis Of Conventional Echocardiographymentioning
confidence: 99%
See 1 more Smart Citation
“…In practice, it is assessed by means of echocardiography, however, in certain cases, inadequate acoustic window and an operator-dependent error, as well as not optimal reproducibility might limit its reliability [11][12][13]. On the other hand, the use of the so-called "gold" standard method, i.e.…”
Section: Discussionmentioning
confidence: 99%