2010 International Conference on High Voltage Engineering and Application 2010
DOI: 10.1109/ichve.2010.5640768
|View full text |Cite
|
Sign up to set email alerts
|

Research on composite material towers used in 110kV overhead transmission lines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 1 publication
0
12
0
Order By: Relevance
“…Li et al. 4 suggested that the tower deflection under normal loading condition and BWC should be around 1% of tower body height. According to the Indian design code, the maximum node displacement of the composite tower meets the requirements.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Li et al. 4 suggested that the tower deflection under normal loading condition and BWC should be around 1% of tower body height. According to the Indian design code, the maximum node displacement of the composite tower meets the requirements.…”
Section: Resultsmentioning
confidence: 99%
“…Tower deflection under BWC has also been found to be maximum at the top which is less than 1% of height of the tower, which also meets the design requirements, as shown in Figure 9. Li et al 4 suggested that the tower deflection under normal loading condition and BWC should be around 1% of tower body height. According to the Indian design code, the maximum node displacement of the composite tower meets the requirements.…”
Section: Analysis Of Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to prevent conductor cross-arm fro m bending and narrowing the safety gap excessively, foam-filled hollow tube is used for cross-arm to improve its flexu ral rigid ity, wh ich makes up for its deficiencies of small elastic modulus and large deflection effectively [6] . And increase FRP insulators rods, which is fixed to the pole via metal hoops [7,8] . Meanwhile, to prevent pollution and lightning flashover, silicone rubber sheath dressing with sheds is added to the hollow FRP tube, which will enhance the creepage distance of FRP cross -arm effectively.…”
Section: ) Materials and Dimension Designmentioning
confidence: 99%
“…Although there are many advantages for the composite TL tower over the metal TL tower [1], [2], it has disadvantages also, such as having none grounding design for the case of lightning protection [3]. The lightning insulation performance for a composite TL tower with double-grounding conductors is analyzed and discussed in [4].…”
Section: Introductionmentioning
confidence: 99%