1998
DOI: 10.1093/oxfordjournals.rpd.a032296
|View full text |Cite
|
Sign up to set email alerts
|

Researches and Applications of ESR Dosimetry for Radiation Accident Dose Assessment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…Extended tests are scheduled to assess the accuracy of this protocol for various time delays between irradiation and storage at low temperature. The dose detection limit for fingernails was previously estimated between 2 and 5 Gy (Romanyukha et al, 2007;Wu et al, 1998;Symons et al, 1995;Dalgarno and Mcclymont, 1989). Clearly it is desirable to carry out additional experiments to more firmly establish the dose-response relationship and limits of detectability.…”
Section: Dose Estimationmentioning
confidence: 99%
See 1 more Smart Citation
“…Extended tests are scheduled to assess the accuracy of this protocol for various time delays between irradiation and storage at low temperature. The dose detection limit for fingernails was previously estimated between 2 and 5 Gy (Romanyukha et al, 2007;Wu et al, 1998;Symons et al, 1995;Dalgarno and Mcclymont, 1989). Clearly it is desirable to carry out additional experiments to more firmly establish the dose-response relationship and limits of detectability.…”
Section: Dose Estimationmentioning
confidence: 99%
“…Based on prior studies there are several factors that need to be taken into account in establishing a protocol for EPR dosimetry with fingernails (Romanyukha et al, 2007;Wu et al, 1998;Symons et al, 1995;Dalgarno and Mcclymont, 1989):…”
Section: Introductionmentioning
confidence: 99%
“…In recent decades, EPR dosimetry on mineral glass was used several times for the estimation of dose to persons who had been accidentally overexposed. Mineral glass from watches was used by Wu et al (1998). More recently, the potential to use the mineral glass from LCD screens found in electronic devices such as mobile phones was explored by Trompier et al (2011).…”
Section: Introductionmentioning
confidence: 99%
“…These requirements are definitely fulfilled by wristwatch glasses. Dosimetric potential of watch glass has been highlighted by various experiments reported in literature [4][5][6][7]. Electron spin resonance and luminescence (both optical and thermal) are among the main techniques used.…”
Section: Introductionmentioning
confidence: 99%