2020
DOI: 10.1016/j.conbuildmat.2019.116969
|View full text |Cite
|
Sign up to set email alerts
|

Residual strength and microstructure of fiber reinforced self-compacting concrete exposed to high temperatures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
29
0
2

Year Published

2021
2021
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 82 publications
(31 citation statements)
references
References 56 publications
0
29
0
2
Order By: Relevance
“…It is important to recognize that, in general, fiber reinforcement is not a substitute for conventional reinforcement [24]. The addition of steel fibers in concrete can improve its toughness [14,[25][26][27][28][29][30][31][32][33][34][35][36][37][38], ductility, and post-crack resistance [29].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…It is important to recognize that, in general, fiber reinforcement is not a substitute for conventional reinforcement [24]. The addition of steel fibers in concrete can improve its toughness [14,[25][26][27][28][29][30][31][32][33][34][35][36][37][38], ductility, and post-crack resistance [29].…”
Section: Introductionmentioning
confidence: 99%
“…Self-Compacted Concrete (SCC) [30] is the concrete which is allowed to compact with its own weight without applying any vibrational effort. The reason for selecting SCC is to avoid steel fiber and aggregate segregation and bleeding.…”
Section: Introductionmentioning
confidence: 99%
“…La pérdida de resistencia a la compresión de muestras de concreto hasta 200°C es casi insignificante, pero será del 40% y 64% cuando la temperatura aumenta en 400°C y 600° C, respectivamente (Sadrmomtazi et al, 2020 Los hormigones con f'c de 25, 35 y 40MPa mostraron pérdida de resistencia tras el enfriamiento brusco. El hormigón con f'c 25 MPa tuvo una reducción de la resistencia proporcional al aumento de temperatura, mientras que los otros hormigones mostraron una reducción de la resistencia más gradual y logarítmica (Coelho et al, 2020).…”
Section: Resistencia a La Compresión Y Módulo De Elasticidadunclassified
“…Over the past decade, extensive research has been conducted on SFRSCC in terms of its workability, mechanical properties, and structural performance with increasing usage in the construction industry [ 14 , 21 , 22 , 23 , 24 , 25 , 26 , 27 ]. Its usage expands to both non-structural and structural applications, such as industrial floors, roads and pavements, sprayed concrete, overlays, composite slabs on steel decking, tunnel lining segments, and precast elements [ 28 ].…”
Section: Introductionmentioning
confidence: 99%