Background/aim: To investigate the effect of positron emission tomography-computed tomography (PET/CT)-based contouring on dosimetric parameters in rectal cancer patients undergoing preoperative intensity-modulated radiation therapy (IMRT).
Materials and methods:Preoperative radiation therapy plans with conformal radiotherapy (CRT) or IMRT were created and examined according to the CT-and PET/CT-based contouring of 20 rectal cancer patients, retrospectively.
Results:The target volumes delineated with PET/CT were significantly larger than the volumes created by CT (P = 0.043). Dose delivered to 98% of the planning target volume was high in IMRT planning contouring with CT and PET/CT compared with CRT planning, but the difference was not statistically significant (P = 0.056). Percent volumes receiving 105% of dose and 110% of dose were low in IMRT planning when compared with CRT (P < 0.0001 and P = 0.044, respectively). The volumes receiving 45 Gy for the small intestine, femur heads, and bladder and the maximum dose received by the bladder were significantly lower in IMRT.
Conclusion:We showed that the target volumes created with PET/CT are significantly larger than the target volumes created with CT and that IMRT provides lower radiation exposure to the tumor-free tissues compared to the CRT planning. The dosimetric results primarily favor IMRT planning in rectal cancer patients and consequently present the significant alteration in target volumes.