2010
DOI: 10.1007/978-3-642-10634-7_7
|View full text |Cite
|
Sign up to set email alerts
|

Results of the Seventh International Comparison of Absolute Gravimeters ICAG-2005 at the Bureau International des Poids et Mesures, Sèvres

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0

Year Published

2010
2010
2012
2012

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(22 citation statements)
references
References 5 publications
1
21
0
Order By: Relevance
“…The AG suppliers have worked with the pilot laboratory at the BIPM (Task Group on Technical Protocol and Budget of Uncertainties of the CCM WGG and the IAG SGCAG 2.1.1) to reach agreement over potential distortions and it was decided that for ICAG 2005 the conventional assignment of the instrument u depending on the type of AGs would be used [8]. The expanded uncertainty U of an AG was then evaluated in principle, according to the International Standardization Organization (ISO) Guide [13].…”
Section: Uncertainties Of Ags a Metrological Kc Results Consists Of Tmentioning
confidence: 99%
See 1 more Smart Citation
“…The AG suppliers have worked with the pilot laboratory at the BIPM (Task Group on Technical Protocol and Budget of Uncertainties of the CCM WGG and the IAG SGCAG 2.1.1) to reach agreement over potential distortions and it was decided that for ICAG 2005 the conventional assignment of the instrument u depending on the type of AGs would be used [8]. The expanded uncertainty U of an AG was then evaluated in principle, according to the International Standardization Organization (ISO) Guide [13].…”
Section: Uncertainties Of Ags a Metrological Kc Results Consists Of Tmentioning
confidence: 99%
“…Table 1 lists the number of AGs which have participated in ICAG meetings. The 7th ICAG and associated RGC took place at the BIPM in 2005 [8][9][10]. The Consultative Committee on Mass and Related Quantities' Working Group on Gravimetry, Study Group 2.1.1 on Comparison of Absolute Gravimeters of the International Association of Geodesy (IAG) and the BIPM jointly organized the 7th ICAG.…”
Section: Introductionmentioning
confidence: 99%
“…Fortunately, portable and easyto-use commercial absolute gravimeters are available that can provide a local value of g with a relative standard uncertainty of a few parts in 10 9 . That these instruments can achieve such a small uncertainty if properly used is demonstrated by a periodic international comparison of absolute gravimeters (ICAG) carried out at the International Bureau of Weights and Measures (BIPM), Sèvres, France; the seventh and most recent, denoted ICAG-2005, was completed in September 2005 (Vitushkin et al, 2005); the next is scheduled for 2009. In the future, atom interferometry or Bloch oscillations using ultracold atoms could provide a competitive or possibly more accurate method for determining a local value of g (Cladé et al, 2005;McGuirk et al, 2002;Peters et al, 2001).…”
Section: Special Quantities and Unitsmentioning
confidence: 99%
“…[6] Intercomparison campaigns have shown systematic errors (offsets) between the different absolute gravimeters that are larger than the declared uncertainties [Vitushkin et al, 2002[Vitushkin et al, , 2010Francis et al, 2005Francis et al, , 2010. Although the offsets can be determined by comparing the instruments, this is always within uncertainties and not always logistically feasible.…”
Section: The Absolute Gravimetermentioning
confidence: 99%
“…Other malfunctioning components may also bias the AG [Wziontek et al, 2008]; this is why, before and after each campaign, the instrument measured at the Membach reference station, where it was compared with the continuously measuring superconducting gravimeter [Van Camp et al, 2005; Van Camp and Francis, 2006]. Finally, the FG5#202 was regularly compared to other AG meters [Robertsson et al, 2001;Vitushkin et al, 2002Vitushkin et al, , 2010Van Camp et al, 2003;Francis et al, 2005Francis et al, , 2010Baumann et al, 2010]. The FG5#202 also benefited from maintenances by the manufacturer in 1998, 2000, 2003, 2005, 2007 and 2010, where it was also compared to other FG5s.…”
Section: The Absolute Gravimetermentioning
confidence: 99%