Results of the study to determine rotablator and transluminal angioplasty strategy (STRATAS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

8
108
2
3

Year Published

2003
2003
2018
2018

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 179 publications
(121 citation statements)
references
References 20 publications
8
108
2
3
Order By: Relevance
“…Rotablation was performed using the "Rotablator" system (Boston Scientific-Scimed Corporation, Natick, MA, USA) after obtaining informed consent from the patient. The size of a drill was chosen so that the drill/artery size ratio was < 0.7 [8]. Rotational speed of the drill was kept within the limits of 140 000-180 000 rotations per minute.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Rotablation was performed using the "Rotablator" system (Boston Scientific-Scimed Corporation, Natick, MA, USA) after obtaining informed consent from the patient. The size of a drill was chosen so that the drill/artery size ratio was < 0.7 [8]. Rotational speed of the drill was kept within the limits of 140 000-180 000 rotations per minute.…”
Section: Methodsmentioning
confidence: 99%
“…Rotational speed of the drill was kept within the limits of 140 000-180 000 rotations per minute. Passage of the drill lasted up to 20 s [8]. During the procedure a continuous flow of unfractionated heparin (5000 U in 500 ml of isotonic saline), verapamil and nitroglycerin was used.…”
Section: Methodsmentioning
confidence: 99%
“…In the present case, the operator following personal experience applied lower speeds with tight control of drill rotation. Studies with bare metal stents proved in fact that decreases in drilling speed during the passage exceeding 5000 rotations per minute are associated with an increased risk of restenosis [12]. No significant drops in rotational speed of the drill were noted during the presented procedure.…”
Section: Stan Po Implantacji 3 Stentów Des Widoczna Dysekcja Ostmentioning
confidence: 86%
“…The diamond particles are 20um in size. The burr comes in various sizes ranging from 1.25um to 2.5um and the burr size to be used is determined on the size of the vessel being treated [6,7]. It is recommended to keep the burr to artery ration of 0.5-0.6.…”
Section: Procedures Descriptionsmentioning
confidence: 99%
“…Short pecking movements are recommended as excessive decelerations (> 14,000-18,000) [7,8] with increased heat generation and thermal injury can increase the risk of peri-procedural myocardial infarctions and restenosis [7].…”