2000
DOI: 10.1006/exer.1999.0804
|View full text |Cite
|
Sign up to set email alerts
|

Retinal Degeneration in the nervous Mutant Mouse. III. Electrophysiological Studies of the Visual Pathway

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
20
0
1

Year Published

2001
2001
2015
2015

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(22 citation statements)
references
References 28 publications
1
20
0
1
Order By: Relevance
“…Similar findings have been reported in other models of mouse retinal degeneration including the nervous mutant 30 rds heterozygotes 50 and a transgenic mouse with a triple substitution in the rhodopsin molecule. 51 Figure 4C shows that a number of the outer segments of surviving photoreceptors are shortened in the mcd/mcd retina.…”
Section: Discussionsupporting
confidence: 88%
See 1 more Smart Citation
“…Similar findings have been reported in other models of mouse retinal degeneration including the nervous mutant 30 rds heterozygotes 50 and a transgenic mouse with a triple substitution in the rhodopsin molecule. 51 Figure 4C shows that a number of the outer segments of surviving photoreceptors are shortened in the mcd/mcd retina.…”
Section: Discussionsupporting
confidence: 88%
“…30 The R max value (ϮSEM) of 370 Ϯ 29 V for mcd/mcd mice was significantly lower than the C57BL/6 mice value of 740 Ϯ 73 V (P Ͻ 0.005). Similarly, a significant reduction in retinal sensitivity of 0.85 log neutral density units was seen in mcd/mcd mice.…”
Section: Electroretinographymentioning
confidence: 79%
“…Electroretinograms were recorded in response to strobe flashes presented in a Ganzfeld bowl under dark-and light-adapted conditions by using protocols described in detail previously (Ren et al, 2000;Ball et al, 2002). In separate sessions, visual evoked potentials were recorded by using a previously described technique (Ren et al, 2000).…”
Section: Visual Electrophysiologymentioning
confidence: 99%
“…Ele está formado por sinais extraídos da atividade elétrica do córtex visual, após impulsos serem gerados em um campo visual central da retina, seguindo pelo nervo óptico, passando pelo corpo geniculado lateral, com radiação óptica até o córtex occipital (OYAMADA, 2000;SALOMÃO, 2007;ODOM et al, 2010). O PVE de varredura é comumente empregado para identificar disfunções no sistema visual, resultante de doenças desmielinizantes, neurite óptica, neuropatias isquêmicas e compressivas, além de servir como recurso para obtenção da Acuidade Visual (AV) em pacientes não verbais e não cooperativos, como crianças e animais (REN et al, 2000). Além de ser utilisado como ferramenta para o diagnóstico de neuropatias, o potencial visual evocado por padrão reverso (PVE-PR) com tabuleiro de xadrez serve como ferramenta para avaliar o impacto destas doenças sobre a função visual em seres humanos (JUERGEN et al, 2014).…”
Section: IIunclassified