2016
DOI: 10.4236/ijmpcero.2016.54033
|View full text |Cite|
|
Sign up to set email alerts
|

RETRACTED: <i>Usefulness of Iron-Containing Fiducial Marker for Prostate Radiotherapy</i>

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2017
2017
2017
2017

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…Gold FMs are usually cylindrically shaped, with a diameter ranging between 0.5 and 1.5 mm and a length between 2 and 10 mm. Typically, three markers are implanted in the prostate prior to treatment and permanently remain in the target after completion of the treatment (Habermehl et al 2013, Ng et al 2014, Tanaka et al 2016. During treatment planning, the FMs are easily localised on the CT images thanks to their high signal and specific streaking artefacts (Nederveen et al 2000, Habermehl et al 2013, Chan et al 2015.…”
Section: Introductionmentioning
confidence: 99%
“…Gold FMs are usually cylindrically shaped, with a diameter ranging between 0.5 and 1.5 mm and a length between 2 and 10 mm. Typically, three markers are implanted in the prostate prior to treatment and permanently remain in the target after completion of the treatment (Habermehl et al 2013, Ng et al 2014, Tanaka et al 2016. During treatment planning, the FMs are easily localised on the CT images thanks to their high signal and specific streaking artefacts (Nederveen et al 2000, Habermehl et al 2013, Chan et al 2015.…”
Section: Introductionmentioning
confidence: 99%
“…The GA used in the present study contains 0.5% iron, and its visibility on MRI has been reported to be superior to that of markers containing no iron [ 7 - 9 ]. Tanaka, et al have directly compared the visibility of the GA with a marker containing no iron in the same patient with prostate cancer and reported the superiority of the GA in terms of the detectability on MRI compared with a marker containing no iron in five patients [ 8 - 9 ]. We assessed four patients with liver tumors as an initial report here; further clinical study is needed in order to compare the possible benefits from the features of the GA objectively.…”
Section: Discussionmentioning
confidence: 99%
“…The fiducial marker was percutaneously placed, under local anesthesia, near the tumor by a hepatobiliary surgeon. The GA was 0.28 mm in diameter, 20 mm in length, and had a shape that could be bent to fold the marker [ 8 - 9 ].…”
Section: Technical Reportmentioning
confidence: 99%
See 1 more Smart Citation