2022
DOI: 10.1055/a-1766-6444
|View full text |Cite|
|
Sign up to set email alerts
|

Retrospective Analysis of 12 Months Glaucoma Implant Efficacy: XEN45 and PreserFlo Microshunt

Abstract: Purpose Several new implant devices have recently been introduced to glaucoma surgery using various techniques for reducing intraocular pressure (IOP). Two implants introduced during the past couple of years, XEN45 and PreserFlo Microshunt, are both designed to control subconjunctival filtration. There are two Swiss multicenter studies that collected the data retrospectively to analyze the efficacy and safety of these two devices separately. In this study, we report the analysis of the combined data … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 21 publications
0
3
1
Order By: Relevance
“…Regarding the number of needling procedures, there was no difference between the two groups. This contrasts with previously published studies in which the needling rate tended to be higher in the XEN group 19 , 21 .…”
Section: Discussioncontrasting
confidence: 99%
See 1 more Smart Citation
“…Regarding the number of needling procedures, there was no difference between the two groups. This contrasts with previously published studies in which the needling rate tended to be higher in the XEN group 19 , 21 .…”
Section: Discussioncontrasting
confidence: 99%
“…There was no statistically significant difference between the two groups. A third study with direct comparison of XEN and MicroShunt as a stand-alone procedure with a follow-up of 12 months was performed at the University Eye Hospital in Basel by Saletta et al [21]. Thirty eyes per group were included.…”
Section: Discussionmentioning
confidence: 99%
“…The literature search yielded a total of 311 articles of which 14 studies (including 1213 PRESERFLO MicroShunt surgeries) were included in the current study and considered eligible for the meta-analysis ( Table S1, Figure S2 ) [ 9 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 ]. Follow-up ranged from 12 months to 72 months.…”
Section: Resultsmentioning
confidence: 99%
“…All patients were treated with a XEN Gel Stent 45 μm through a classic ab interno approach as described previously in multiple publications, e.g., Fae et al [ 19 ], Vera et al [ 12 ] and Saletta et al [ 20 ]. The XEN45 implantation was performed as a standalone surgery or in combination with phacoemulsification cataract surgery.…”
Section: Methodsmentioning
confidence: 99%