2018
DOI: 10.5761/atcs.oa.18-00019
|View full text |Cite|
|
Sign up to set email alerts
|

Retrospective Analysis of Air Handling by Contemporary Oxygenators in the Setting of Cardiac Surgery

Abstract: Purpose: Cardiac surgery with the use of extracorporeal circulation is associated with a significant risk for gaseous microemboli (GME) despite excellent surgical techniques and highest operative standards. GME are associated with postoperative neurocognitive dysfunction and negative clinical outcome. This study determines whether oxygenator design has influence on perioperative outcome after cardiac surgery.Methods: Three different oxygenator models with integrated arterial filter (HiliteAF 7000, Fusion Affin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 19 publications
1
1
0
Order By: Relevance
“…We decided to use the Inspire in the comparison population as it represents the method routinely used in our center. According to the literature data [19,22], the results in terms of bubble removal are comparable to other oxygenators such as Fusion or Quadrox. To our knowledge, there are no studies of this type comparing different filters.…”
Section: Discussionsupporting
confidence: 57%
See 1 more Smart Citation
“…We decided to use the Inspire in the comparison population as it represents the method routinely used in our center. According to the literature data [19,22], the results in terms of bubble removal are comparable to other oxygenators such as Fusion or Quadrox. To our knowledge, there are no studies of this type comparing different filters.…”
Section: Discussionsupporting
confidence: 57%
“…RemoweLL 2 is designed to reduce neurological injury and inflammatory response in patients undergoing cardiac surgery, thanks to its unique and patented cardiotomy features capable to reduce lipids and leukocytes coming from pericardial suction blood, it has a cardiotomy capacity of 800 mL, and it depletes lipids-leukocytes in two steps: a multilayer cascade filtration, for lipids and leukocytes, and a supernatant separator for lipids only). Data in the literature suggest that RemoweLL 2 technology is effective in the filtration of LME (Lipid Micro Emboli) in the clinical setting and the subsequent attenuation of NSE (neuron-specific enolase) release, a known marker of neurologic injury [19].…”
Section: Blood Oxygenatorsmentioning
confidence: 99%