2018
DOI: 10.3390/s18113976
|View full text |Cite
|
Sign up to set email alerts
|

Reusability of SPE and Sb-modified SPE Sensors for Trace Pb(II) Determination

Abstract: In this work, unmodified screen-printed electrode (bare SPE) and Sb-film modified SPE (SbFSPE) sensors were employed for the analysis of trace amounts of Pb(II) in non-deaerated water solutions. The modified electrode was performed in situ in 0.5 mg/L Sb(III) and 0.01 M HCl. The methodology was validated for an accumulation potential of –1.1 V vs. Ag/AgCl and an accumulation time of 60 s. A comparative analysis of bare SPE and SbFSPE showed that the detection and quantification limits decrease for the bare SPE… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 36 publications
3
7
0
Order By: Relevance
“…The simplex optimization procedure did not have a significant influence on the LOD and LOQ for these in situ FEs. These values were in the same range as reported previously [ 22 , 24 , 39 ].…”
Section: Resultssupporting
confidence: 89%
See 3 more Smart Citations
“…The simplex optimization procedure did not have a significant influence on the LOD and LOQ for these in situ FEs. These values were in the same range as reported previously [ 22 , 24 , 39 ].…”
Section: Resultssupporting
confidence: 89%
“…The simplex optimization procedure did not have a significant influence on the LOD and LOQ for these in situ FEs. These values were in the same range as reported previously [22,24,39]. The LOD is the lowest concentration where the signal can be confidently distinguished from the noise, and the LOQ is the lowest concentration at which quantification is possible.…”
Section: The Linearity Sensitivity Lod Loq and Precision Of The Ssupporting
confidence: 79%
See 2 more Smart Citations
“…Alternative techniques such as anodic stripping voltammetry have also been employed, but have suffered from the use of relatively large amounts of Hg required for their application. However, a number of Hg-free devices have been reported, made possible by either the in situ or ex situ deposition of other less toxic metal films, such as Bi [ 10 ], Sb [ 11 ] or, more recently, Cu [ 12 ] and Sn [ 13 ]. Nevertheless, some disadvantages of the application of metal film-based electrodes have been highlighted [ 14 ].…”
Section: Introductionmentioning
confidence: 99%