2017
DOI: 10.1007/s40005-017-0312-1
|View full text |Cite
|
Sign up to set email alerts
|

Reverse engineering and formulation by QBD of olopatadine hydrochloride ophthalmic solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 2 publications
0
6
0
Order By: Relevance
“…The DSC thermograms of olopatadine HCl, ethyl cellulose (10 cp), and microparticles (MP-1:1, MP-1:2, and MP-1:3) are shown in Supplementary Material (Part F). Olopatadine HCl showed characteristic single sharp endothermic peak at 253.9 C [enthalpy of fusion 125.08 J/g], corresponding to its melting point 59 and crystalline nature. There was a noticeable reduction and broadening in the endothermic peaks of olopatadine HCleloaded ethyl cellulose microparticles as compared to olopatadine HCl.…”
Section: Differential Scanning Calorimetry (Dsc)mentioning
confidence: 99%
“…The DSC thermograms of olopatadine HCl, ethyl cellulose (10 cp), and microparticles (MP-1:1, MP-1:2, and MP-1:3) are shown in Supplementary Material (Part F). Olopatadine HCl showed characteristic single sharp endothermic peak at 253.9 C [enthalpy of fusion 125.08 J/g], corresponding to its melting point 59 and crystalline nature. There was a noticeable reduction and broadening in the endothermic peaks of olopatadine HCleloaded ethyl cellulose microparticles as compared to olopatadine HCl.…”
Section: Differential Scanning Calorimetry (Dsc)mentioning
confidence: 99%
“…As shown in Figure 5, probability maps were drawn using MODDE software, based on the calculated model of particle size and zeta potential and the Monte Carlo simulation for RA [37]. Monte Carlo simulations were performed for error propagation for the function relating the independent variables to the dependent variables, giving distributions of dependent variables (i.e., resolutions) for each operating condition of the response surface methodology [38][39][40]. The design space established by the Monte Carlo simulation is expected to be considerably smaller than that of the overlay plot.…”
Section: Establishment Of the Design Spacementioning
confidence: 99%
“…The current procedure will help make the generic formulation. Ahmed et al 1 did the reverse engineering study for OPT nasal spray 0.1% only by utilizing the different solubility techniques, but the proposed article clearly stated that the research was done at the academic level. The methods used for the study had a sensitivity issue.…”
Section: Introductionmentioning
confidence: 99%