2017
DOI: 10.1080/03067319.2017.1336234
|View full text |Cite
|
Sign up to set email alerts
|

Reversed phase StrataTM-X resin as sorbent for automatic on-line solid phase extraction atomic absorption spectrometric determination of trace metals: comparison of polymeric-based sorbent materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…The developed method features satisfactory sensitivity and precision (relative standard deviations, or RSD) with better detection limits (except [24]) and similar precision (RSD) for the lead determination. For chromium(VI) determination, comparable detection limits and precision have been observed with a lower preconcentration time (except [29,30]). PT: preconcentration time, SC: sample consumption, RSD: relative standard deviation, LOD: limit of detection, EF: enrichment factor, GF: Sol-gel PDPS: glass fiber coated with sol-gel poly-diphenylsiloxane, PS-NAPdien: chloromethylated polystyrene functionalized with N,N-bis(naphthylideneimino)diethylenetriamine, THAM: tris(hydroxymethyl)methylamine.…”
Section: Figures Of Meritmentioning
confidence: 83%
See 1 more Smart Citation
“…The developed method features satisfactory sensitivity and precision (relative standard deviations, or RSD) with better detection limits (except [24]) and similar precision (RSD) for the lead determination. For chromium(VI) determination, comparable detection limits and precision have been observed with a lower preconcentration time (except [29,30]). PT: preconcentration time, SC: sample consumption, RSD: relative standard deviation, LOD: limit of detection, EF: enrichment factor, GF: Sol-gel PDPS: glass fiber coated with sol-gel poly-diphenylsiloxane, PS-NAPdien: chloromethylated polystyrene functionalized with N,N-bis(naphthylideneimino)diethylenetriamine, THAM: tris(hydroxymethyl)methylamine.…”
Section: Figures Of Meritmentioning
confidence: 83%
“…The analytical performance data of the proposed method together with that of other on-line solid phase extraction methods for lead and chromium(VI) determination with FAAS, reported in the recent literature [16,17,[24][25][26][27][28][29][30][31][32][33][34][35], are given in Table 3. The developed method features satisfactory sensitivity and precision (relative standard deviations, or RSD) with better detection limits (except [24]) and similar precision (RSD) for the lead determination.…”
Section: Figures Of Meritmentioning
confidence: 99%
“…The figures of merit of the proposed FI-FDSE-FAAS method and other selected on-line SPE methods coupled to FAAS [8,10,12,14,15,18,24,[30][31][32][33][34][35][36][37][38][39][40][41][42][43], are compiled in Table S1 (Supplementary Materials). The proposed method features good sensitivity and precision with better or similar detection limits than earlier works for Cu(II) [8,15,31,32,34], Ni(II) [8,[38][39][40], Zn(II) [41][42][43], Pb(II) [8,24], and Cd(II) [24] assays, using a shorter preconcentration time.…”
Section: Analytical Performance Characteristicsmentioning
confidence: 99%
“…Among them, APDC has been found to be more suitable for atomic absorption especially at low pH values than other dithiocarbamates. It is worth mentioning that APDC forms stable complexes with a large number of metals and for this reason it is widely used in extraction procedures [18,29]. APDC is a highly polar chelating agent with logKow < 1.10.…”
Section: Retention Of the Analytes Onto The Microcolumnmentioning
confidence: 99%