Revision Total Hip Arthroplasty Using a Modular Cementless Distal Fixation Prosthesis: The Zmr® Hip System. Clinical and Radiographic Analysis of 30 Cases

Abstract: Objective: To evaluate the clinical and radiographic results from 30 cases of revision of total hip arthroplasty using a modular cementless distal fixation prosthesis: the ZMR® Hip System. Method: Between July 2005 and December 2008, 30 operations were performed, on 14 men and 14 women. Two male patients had bilateral surgery. The mean age was 59.2 years (29-81 years), with a mean follow-up of 24 months. The Paprosky classification was used for periprosthetic bone loss, and the Harris Hip Score (HHS) was used … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 30 publications
0
2
0
Order By: Relevance
“…First, it is a retrospective study with a small sample size. However, series of revision THA in the literature are usually small (3,23,29,52). Second, though none of the patients showed or reported any adverse reactions or symptoms of metallosis, we did not test serum metal ion levels to demonstrate that these were within normal safe ranges.…”
Section: Discussionmentioning
confidence: 93%
“…First, it is a retrospective study with a small sample size. However, series of revision THA in the literature are usually small (3,23,29,52). Second, though none of the patients showed or reported any adverse reactions or symptoms of metallosis, we did not test serum metal ion levels to demonstrate that these were within normal safe ranges.…”
Section: Discussionmentioning
confidence: 93%
“…One possible reason for the supposed absence of ALTR with these stems until now is the fact that they are made of titanium alloy, which shows less fretting and crevice corrosion than cobaltchromium-molybdenum implants. 53 Several other modular fluted tapered stems have also demonstrated favorable outcomes in revision arthroplasty at short-to mid-term follow-up, 41,[54][55][56][57][58] indicating that this stem design is useful clinically. It must be emphasized, however, that is not possible to claim that modular fluted tapered stems perform better than other implants in femoral revision arthroplasty.…”
Section: Discussionmentioning