Rigid gas-permeable contact lens fitting in LASIK patients for the correction of multifocal corneas

Abstract: Contact lenses with large diameters, in combination with selection of the back optic zone radius 0.2 mm peripheral of the refractive ablation zone, facilitate contact lens fitting to restore best-corrected visual acuity in LASIK patients with multifocal corneas.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
11
0
1

Year Published

2004
2004
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(13 citation statements)
references
References 18 publications
1
11
0
1
Order By: Relevance
“…Our chosen CVK reference points are measuring corneal curvatures approximately 0.2 mm or 0.7 mm peripheral to the topographic optic zone on tangential or axial displays, respectively. These data correlate well with those of Eggink et al, 10 who used tangential maps to find the curvature 0.2 mm outside the "refractive ablation zone" for GP fitting after LASIK. They also fit lenses with a large back optic zone diameter (range, 8.3-8.5 mm) with good success.…”
Section: Figsupporting
confidence: 86%
See 3 more Smart Citations
“…Our chosen CVK reference points are measuring corneal curvatures approximately 0.2 mm or 0.7 mm peripheral to the topographic optic zone on tangential or axial displays, respectively. These data correlate well with those of Eggink et al, 10 who used tangential maps to find the curvature 0.2 mm outside the "refractive ablation zone" for GP fitting after LASIK. They also fit lenses with a large back optic zone diameter (range, 8.3-8.5 mm) with good success.…”
Section: Figsupporting
confidence: 86%
“…myopic keratorefractive surgery. Eggink et al 10 used tangential maps to fit eight eyes after LASIK. They recommended selecting a point 0.2 mm outside of the "refractive ablation zone," as measured by a tangential display.…”
Section: Figmentioning
confidence: 99%
See 2 more Smart Citations
“…Além das complicações acima citadas, têm-se também córneas multifocais e flutuação da visão (2)(3)(4) . Em estudo feito por Astin e col. (5)(6) , as lentes de contato levaram a uma melhora da acuidade visual, e em casos de moderado astigmatismo irregular houve significante melhora em relação ao uso de óculos.…”
Section: Introductionunclassified