2015
DOI: 10.1007/s40477-015-0170-5
|View full text |Cite
|
Sign up to set email alerts
|

Role of US in evaluating breast implant integrity

Abstract: US can be used as the first examination in patients with breast implants. US intra-capsular rupture detection requires further evaluation by MRI; in case of extra-capsular rupture US diagnosis, surgical implant removal could be proposed without further investigations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
2

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(25 citation statements)
references
References 19 publications
0
23
2
Order By: Relevance
“…Therefore, ultrasound remains an indispensable, complementary method for the further classification of lesions detected on mammography or CT, in symptomatic women, women with dense breasts and for the assessment of implant integrity. [ 11 , 28 , 29 ] Although ultrasound has undergone remarkable improvement in recent years with increased resolution and the utilization of additional parameters, such as elastic modules, it is by itself not sufficient for breast cancer screening and diagnosis as a stand-alone method due to its decreased sensitivity in detecting DCIS and small tumors in breasts characterized by shadowing and fibrocystic changes. [ 29 31 ] B-CT covers these limitations.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, ultrasound remains an indispensable, complementary method for the further classification of lesions detected on mammography or CT, in symptomatic women, women with dense breasts and for the assessment of implant integrity. [ 11 , 28 , 29 ] Although ultrasound has undergone remarkable improvement in recent years with increased resolution and the utilization of additional parameters, such as elastic modules, it is by itself not sufficient for breast cancer screening and diagnosis as a stand-alone method due to its decreased sensitivity in detecting DCIS and small tumors in breasts characterized by shadowing and fibrocystic changes. [ 29 31 ] B-CT covers these limitations.…”
Section: Discussionmentioning
confidence: 99%
“…Ultrasound presents a moderately good modality in augmented breasts as implant integrity can be assessed, [ 11 ] but it is not sufficient for breast cancer screening as a stand-alone method. [ 12 ]…”
Section: Introductionmentioning
confidence: 99%
“…The appearance of an intact breast implant on ultrasound is similar to a large cyst, with presence of an anechoic implant lumen surrounded by a hyperechoic linear shell [13]. The "stepladder sign," which appears as horizontal, hyperechoic, straight, or curvilinear lines across the implant lumen, is characteristic of intracapsular silicone implant rupture (Figure 4) [13]. The "snowstorm sign" is reportedly the most significant sonographic finding for extracapsular rupture and appears as hyperechoic nodules with defined anterior margin and posterior acoustic shadowing within the breast parenchyma or axillary lymph nodes [13].…”
Section: The Postimplant Breastmentioning
confidence: 98%
“…While MRI is the imaging modality of choice to evaluate for silicone implant integrity, there are characteristic sonographic appearances associated with silicone implant rupture. The appearance of an intact breast implant on ultrasound is similar to a large cyst, with presence of an anechoic implant lumen surrounded by a hyperechoic linear shell [13]. The "stepladder sign," which appears as horizontal, hyperechoic, straight, or curvilinear lines across the implant lumen, is characteristic of intracapsular silicone implant rupture (Figure 4) [13].…”
Section: The Postimplant Breastmentioning
confidence: 99%
See 1 more Smart Citation