2018
DOI: 10.1177/1076029618797472
|View full text |Cite
|
Sign up to set email alerts
|

Rotational Thromboelastometry for Assessing Bleeding Complications and Factor XIII Deficiency in Cardiac Surgery Patients

Abstract: We aimed to detect alterations and deficits in hemostasis during cardiac surgery with cardiopulmonary bypass (CPB) using point-of-care-supported coagulation analysis (rotational thromboelastometry, impedance aggregometry), in addition to single factor assays for the measurement of fibrinogen (FI) and factor XIII (FXIII) levels. Forty-one patients scheduled for elective cardiac surgery with CPB were enrolled in this observational study. Perioperative measurement (pre-, postheparin, 30-minutes before the end of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
14
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 27 publications
1
14
0
1
Order By: Relevance
“…As FXIII circulates in a complex with fibrinogen, fibrinogen levels could be a marker of FXIII activity. 16,27 However, similarly to other authors, 17 we did not find any correlation between FXIII deficiency and a drop in fibrinogen levels, suggesting that fibrinogen might not be an accurate predictor of FXIII deficiency. Since rapid evaluation of FXIII levels is not available in most centers, FXIII deficiency could be indirectly investigated through viscoelastic assays.…”
Section: Discussionsupporting
confidence: 80%
See 1 more Smart Citation
“…As FXIII circulates in a complex with fibrinogen, fibrinogen levels could be a marker of FXIII activity. 16,27 However, similarly to other authors, 17 we did not find any correlation between FXIII deficiency and a drop in fibrinogen levels, suggesting that fibrinogen might not be an accurate predictor of FXIII deficiency. Since rapid evaluation of FXIII levels is not available in most centers, FXIII deficiency could be indirectly investigated through viscoelastic assays.…”
Section: Discussionsupporting
confidence: 80%
“…28 Nonetheless, impaired clot firmness in the ExTEM assay (which activates hemostasis via the activator tissue factor) and the FibTEM assay (which measures the fibrin part of the clot) has been shown to correlate with FXIII concentrations in several clinical studies. 15,17,27 These tests could possibly be harnessed to optimize clinical management through bedside monitoring.…”
Section: Discussionmentioning
confidence: 99%
“…With a cut-off value of 25 mm for A5 EX (35 mm for A10 EX and 45 mm for MCF EX ) and a cut-off value of 8 mm for A5 FIB (9 mm for A10 FIB and 10 mm for MCF FIB ), lower levels of clot firmness seem to be adequate in liver transplantation compared to the cardiovascular, trauma, and obstetric setting. Notably, FIBTEM is superior to predict bleeding in liver transplantation compared to plasma fibrinogen concentration since it does not only assess the quantity of fibrinogen but also fibrin polymerization that is affected by dysfibrinogens, factor XIII activity, and colloids [110][111][112][113]. Implementation of FIBTEM-guided fibrinogen substitution in bleeding management algorithms during liver transplantation significantly reduced transfusion requirements for red blood cells, plasma, and platelets [31,92,97,101,[114][115][116][117][118].…”
Section: Vol 72 No 4 August 2019mentioning
confidence: 99%
“…Based on our findings, EXTEM A5 and EXTEM A10 proved to be stronger predictors of hemorrhage in thrombocytopenic neonates compared to ROTEM variables based on clot elasticity and platelet component. This finding could be attributed to the fact that EXTEM A5 and EXTEM A10 encompass platelet count, platelet function, fibrinogen concentration, fibrin polymerization, and factor XIII contribution in clot firmness 22,23 . Therefore, they better reflect the compensatory effect of increased fibrin polymerization on decreased platelet count in thrombocytopenic patients 24,25 .…”
Section: Discussionmentioning
confidence: 99%
“…This finding could be attributed to the fact that EXTEM A5 and EXTEM A10 encompass platelet count, platelet function, fibrinogen concentration, fibrin polymerization, and factor XIII contribution in clot firmness. 22,23 Therefore, they better reflect the compensatory effect of increased fibrin polymerization on decreased platelet count in thrombocytopenic patients. 24,25 This effect is also demonstrated in our study, by the significantly higher FIBTEM A10…”
Section: Discussionmentioning
confidence: 99%