Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
(English) This thesis describes experiments that employ squeezed light to improve the performance of a sensitive optically-pumped magnetometer (OPM). The squeezed light source employs parametric amplification of vacuum fluctuations to produce squeezed vacuum and polarization-squeezed light tunable around the Rb D1 line. The OPM employs Bell-Bloom optical pumping of a high density vapor (with atom number density 10^{13}) and paramagnetic Faraday rotation, also on the Rb D1 line. The setup allows convenient switching from probing with laser light to probing with polarization-squeezed light, to study the use of the latter in atomic magnetometry. The magnetometer shows sub-pT/Hz^{1/2} sensitivity, limited by quantum noise; spin projection noise at low frequencies (<100Hz) and photon shot noise at high frequencies. Probing with polarization squeezed light suppresses the photon shot noise by 2dB, limited by the available squeezing and optical losses in passing through the vapor. This shot-noise suppression improves the high-frequency sensitivity and increases the measurement bandwidth, with no observed loss of sensitivity at any frequency. This result confirms experimentally the expected evasion of measurement back-action noise in the Bell-Bloom magnetometer. The thesis also develops a physical model to explain the observed spin dynamics of the Bell-Bloom magnetometer. The model describes the combined spin and optical polarization dynamics using Bloch equations with stochastic drive and detection noise terms. A perturbative approach and Fourier methods are then used to obtain analytic expressions for the magnetometer's frequency response, spin projection noise and photon shot noise. The role of measurement back-action emerges from a study of this model. As polarization squeezing reduces optical noise in the detected Stokes parameter, the accompanying ellipticity anti-squeezing is shunted into the unmeasured spin component. The thesis also reports a study of squeezed-light-enhanced magnetometry at a range of atomic densities, from 2.18 10^{12} atoms/cm3 to 1.13 10^{13} atoms/cm3 . Operating with fixed conditions of optical pumping, the signal amplitude, instrument noise spectrum and magnetic resonance width are measured as a function of atomic number density, for both laser- and squeezed-light probing. The equivalent magnetic noise spectra are then calculated. In the photon-shot-noise-limited portion of the spectrum, the squeezed light probing improves the magnetometer's sensitivity and measurement bandwidth for the full range of atomic density values. In particular, the laser-probed magnetometer shows a sensitivity optimum at n ~ 6 10 ^{12} atoms/cm3, and the squeezed-light-probed magnetometer surpasses this sensitivity. The thesis concludes with a discussion of the potential of stronger optical squeezing to enhance the instrument's sensitivity in different portions of the spectrum. Using the theory model we estimate the enhancement of the equivalent magnetic noise spectrum for 2 dB , 5.6 dB and perfect squeezing (zero noise in the detected polarization component) at the input to the atomic medium. (Català) Aqueta tesi descriu la millora d’un magnetòmetre de bombeig òptic (OPM) mitjançant l’ús d’estats de llum amb incertesa comprimida (squeezed states). S’usa amplificació paramètrica per a comprimir la incertesa de la font de llum. En concret, es comprimeix la incertesa de l’estat de buit quàntic, com també de la polarització òptica, amb la possibilitar d’ajustar la longitud d’ona al voltant de la transició atòmica D1 de 87Rb. L’OPM usa bombeig òptic Bell-Bloom de vapors d’alta densitat (amb densitats atòmiques properes a 1013) i rotació de Faraday, també al voltant de la transició atòmica D1 de 87Rb. L’aparell experimental permet canviar de mostreig amb llum coherent làser a mostreig amb llum de polarització comprimida, amb la finalitat d’avaluar el seu impacte en la sensitivitat del magnetòmetre. El magnetòmetre té una sensitivitat de sub-pT{ ?Hz , principalment limitada per soroll quàntic; soroll de projecció de spin a baixes freqüències (À 100 Hz) i soroll de quantització fotònica a altes freqüències. L’ús d’estats de llum amb polarització comprimida permet reduir el soroll fotònic en „ 2 dB, limitat per la compressió disponible i les pèrdues en travessar el vapor atòmic. La supressió del soroll fotònic augmenta l’amplada de banda del sistema amb l’avantatge de no perdre sensitivitat a cap banda de freqüència. Els resultats experimentals confirmen l’esperada supressió de retroalimentació de soroll en magnetòmetres de Bell-Bloom. La tesi també estudia el model teòric darrere les dinàmiques de spin en un magnetòmetre de tipus Bell-Bloom. El model descriu la combinació de les dinàmiques de spin i de la polarització òptica mitjançant equacions de Bloch forcades estocàsticament i amb termes de soroll de detecció. Es treballa en el límit pertorbatiu on mitjançant mètodes de Fourier s’obtenen expressions analítiques de la resposta en freqüència del magnetòmetre, dels sorolls de projecció de spin i del soroll de quantització fotònica. El rol de la retroalimentació de soroll també s’extrau d’aquest model. En concret, s’observa que la compressió en polarització redueix el soroll en els paràmetres de Stokes detectats, mentre els paràmetres de spin no mesurats experimenten una expansió de la seva incertesa (anti-squeezing). La tesi estudia magnetòmetres òptics de llum amb incertesa comprimida per a densitats entre 2.18 ˆ 1012 atoms{cm3 i 1.13 ˆ 1013 atoms{cm3. Es mesuren l’amplitud de senyal, l’espectre de soroll i l’amplada de la ressonància magnètica en funció de la densitat atòmica, per a un bombeig òptic constant i per a ambdós tipus de mostreig òptic (llum coherent i llum de polarització comprimida). A continuació, es calculen els espectres de soroll equivalents. En la part d’espectre on domina el soroll de quantització fotònica, s’observa que l’ús de llum de polarització comprimida millora la sensitivitat del magnetòmetre al llarg de tot el rang de densitats atòmics. En concret, la sensitivitat del magnetòmetre amb mostreig coherent és òptima per a n « 6ˆ1012 atoms{cm3 i es demostra una millora amb l’ús de mostreig amb llum comprimida. Es conclou amb una discussió sobre l’efecte de compressions més severes en la sensitivitat del magnetòmetre. Mitjançant el model teòric s’estima la millora en la sensitivitat per a compressions de 2 dB, 5.6 dB i “compressió perfecta” a l’entrada del medi atòmic
(English) This thesis describes experiments that employ squeezed light to improve the performance of a sensitive optically-pumped magnetometer (OPM). The squeezed light source employs parametric amplification of vacuum fluctuations to produce squeezed vacuum and polarization-squeezed light tunable around the Rb D1 line. The OPM employs Bell-Bloom optical pumping of a high density vapor (with atom number density 10^{13}) and paramagnetic Faraday rotation, also on the Rb D1 line. The setup allows convenient switching from probing with laser light to probing with polarization-squeezed light, to study the use of the latter in atomic magnetometry. The magnetometer shows sub-pT/Hz^{1/2} sensitivity, limited by quantum noise; spin projection noise at low frequencies (<100Hz) and photon shot noise at high frequencies. Probing with polarization squeezed light suppresses the photon shot noise by 2dB, limited by the available squeezing and optical losses in passing through the vapor. This shot-noise suppression improves the high-frequency sensitivity and increases the measurement bandwidth, with no observed loss of sensitivity at any frequency. This result confirms experimentally the expected evasion of measurement back-action noise in the Bell-Bloom magnetometer. The thesis also develops a physical model to explain the observed spin dynamics of the Bell-Bloom magnetometer. The model describes the combined spin and optical polarization dynamics using Bloch equations with stochastic drive and detection noise terms. A perturbative approach and Fourier methods are then used to obtain analytic expressions for the magnetometer's frequency response, spin projection noise and photon shot noise. The role of measurement back-action emerges from a study of this model. As polarization squeezing reduces optical noise in the detected Stokes parameter, the accompanying ellipticity anti-squeezing is shunted into the unmeasured spin component. The thesis also reports a study of squeezed-light-enhanced magnetometry at a range of atomic densities, from 2.18 10^{12} atoms/cm3 to 1.13 10^{13} atoms/cm3 . Operating with fixed conditions of optical pumping, the signal amplitude, instrument noise spectrum and magnetic resonance width are measured as a function of atomic number density, for both laser- and squeezed-light probing. The equivalent magnetic noise spectra are then calculated. In the photon-shot-noise-limited portion of the spectrum, the squeezed light probing improves the magnetometer's sensitivity and measurement bandwidth for the full range of atomic density values. In particular, the laser-probed magnetometer shows a sensitivity optimum at n ~ 6 10 ^{12} atoms/cm3, and the squeezed-light-probed magnetometer surpasses this sensitivity. The thesis concludes with a discussion of the potential of stronger optical squeezing to enhance the instrument's sensitivity in different portions of the spectrum. Using the theory model we estimate the enhancement of the equivalent magnetic noise spectrum for 2 dB , 5.6 dB and perfect squeezing (zero noise in the detected polarization component) at the input to the atomic medium. (Català) Aqueta tesi descriu la millora d’un magnetòmetre de bombeig òptic (OPM) mitjançant l’ús d’estats de llum amb incertesa comprimida (squeezed states). S’usa amplificació paramètrica per a comprimir la incertesa de la font de llum. En concret, es comprimeix la incertesa de l’estat de buit quàntic, com també de la polarització òptica, amb la possibilitar d’ajustar la longitud d’ona al voltant de la transició atòmica D1 de 87Rb. L’OPM usa bombeig òptic Bell-Bloom de vapors d’alta densitat (amb densitats atòmiques properes a 1013) i rotació de Faraday, també al voltant de la transició atòmica D1 de 87Rb. L’aparell experimental permet canviar de mostreig amb llum coherent làser a mostreig amb llum de polarització comprimida, amb la finalitat d’avaluar el seu impacte en la sensitivitat del magnetòmetre. El magnetòmetre té una sensitivitat de sub-pT{ ?Hz , principalment limitada per soroll quàntic; soroll de projecció de spin a baixes freqüències (À 100 Hz) i soroll de quantització fotònica a altes freqüències. L’ús d’estats de llum amb polarització comprimida permet reduir el soroll fotònic en „ 2 dB, limitat per la compressió disponible i les pèrdues en travessar el vapor atòmic. La supressió del soroll fotònic augmenta l’amplada de banda del sistema amb l’avantatge de no perdre sensitivitat a cap banda de freqüència. Els resultats experimentals confirmen l’esperada supressió de retroalimentació de soroll en magnetòmetres de Bell-Bloom. La tesi també estudia el model teòric darrere les dinàmiques de spin en un magnetòmetre de tipus Bell-Bloom. El model descriu la combinació de les dinàmiques de spin i de la polarització òptica mitjançant equacions de Bloch forcades estocàsticament i amb termes de soroll de detecció. Es treballa en el límit pertorbatiu on mitjançant mètodes de Fourier s’obtenen expressions analítiques de la resposta en freqüència del magnetòmetre, dels sorolls de projecció de spin i del soroll de quantització fotònica. El rol de la retroalimentació de soroll també s’extrau d’aquest model. En concret, s’observa que la compressió en polarització redueix el soroll en els paràmetres de Stokes detectats, mentre els paràmetres de spin no mesurats experimenten una expansió de la seva incertesa (anti-squeezing). La tesi estudia magnetòmetres òptics de llum amb incertesa comprimida per a densitats entre 2.18 ˆ 1012 atoms{cm3 i 1.13 ˆ 1013 atoms{cm3. Es mesuren l’amplitud de senyal, l’espectre de soroll i l’amplada de la ressonància magnètica en funció de la densitat atòmica, per a un bombeig òptic constant i per a ambdós tipus de mostreig òptic (llum coherent i llum de polarització comprimida). A continuació, es calculen els espectres de soroll equivalents. En la part d’espectre on domina el soroll de quantització fotònica, s’observa que l’ús de llum de polarització comprimida millora la sensitivitat del magnetòmetre al llarg de tot el rang de densitats atòmics. En concret, la sensitivitat del magnetòmetre amb mostreig coherent és òptima per a n « 6ˆ1012 atoms{cm3 i es demostra una millora amb l’ús de mostreig amb llum comprimida. Es conclou amb una discussió sobre l’efecte de compressions més severes en la sensitivitat del magnetòmetre. Mitjançant el model teòric s’estima la millora en la sensitivitat per a compressions de 2 dB, 5.6 dB i “compressió perfecta” a l’entrada del medi atòmic
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.